The new generation tester for diamond fraud protection, the GemOro PRO-D 3, features enhanced testing abilities, sleek ergonomics and more! OPERATING PROCEDURE & OWNERS MANUAL Congratulations on your purchase of the PRO-D 3 from GemOro Superior Instruments, the most trusted name in gemological instrumentation for the jewelry industry.
3 is a helpful screening tool that by design is to be used as a quick method for helping to identify diamonds. The PRO-D 3 should not be used as the final method for determining the authenticity or identity of the gemstone being tested.
Page 4
CONDITIONS FOR IDEAL OPERATION 1. The PRO-D 3 should be used in the following environmental conditions. Both the tester and the stone being tested must be the same temperature. By not following these instructions you risk compromising the accuracy of the test.
Page 5
Blowing on the stone is recommended and will speed up this process. Please be aware that if while testing a stone the Pro-D 3 light pipe turns pink, unless it is a white sapphire or sapphire watch crystal, odds are...
Page 6
5 minutes of non-use. After powering down, if you wish to resume using the PRO-D 3, simply touch the tester’s power button and within seconds the tester will turn itself back on again.
Page 7
12. Glowing LED Light Pipe and Probe Tip Indicator. Innovative PATENTED colored LEDs visually indicate (see images): GREEN = Diamond PINK = Sapphire = Metal Alert DIAMOND SAPPHIRE METAL ALERT...
• Working Temperature: 65°F-80°F (18°C-27°C). • Air Relative Humidity: 45%-75%. • Net Weight: Approximately 100g (including batteries). CAUTION DO NOT disassemble the PRO-D 3 other than to replace the batteries or the warranty will become void. GEMORO PRO-D 3...
1. NiMH Battery Usage and Alkaline Battery Installation: Remove the battery compartment door located on the end of the PRO-D 3 by using your thumb to slide the textured area down and in the direction of the arrow. activate the (3) NiMH rechargeable...
Page 10
Carefully replace the battery compartment door. BATTERY POLARITY 2. The PRO-D 3 batteries may be charged by placing it in the optional UltraDock 3 battery charging station with the micro-USB power cord plugged into...
Page 11
AC adapter. 3. To turn the PRO-D 3 ON press the oval shaped power button, located on the top center edge of the tester and hold it down for approximately one second, then release the button.
Page 12
PRO-D 3 is not in use. PROBE TIP CAP 6. To properly hold the PRO-D 3, it is important to grasp the tester with your thumb and forefinger while touching them to the PATENT PENDING finger pads located on either side of the tester.
Page 13
You may also attach the optional GemOro Test Stone Magnifier to the Pro-D 3 by clipping it onto the end of the tester’s probe tip cone. This will allow you to see a magnified view of the stone being tested and help ensure...
Page 14
While holding the PRO-D 3 in your other hand, firmly touch the probe tip to the loose stone’s “table” (see image) until the test result it indicated. YOU MUST...
Page 15
USB into its AC power cube adapter. Plug the adapter into a convenient wall outlet. You may now simply place the PRO-D 3 in the charging stations cradle with its on bottom edge facing down, and the rear of the PRO-D 3 facing the back end of the cradle.
Page 16
12. Using the Optional Test Stone Magnifier: Insert the PRO-D 3’s probe tip cone through the wider opening of the magnifiers oval shaped bracket and clip it into place. Depending on whether you are right or left handed, you may conveniently position it on either side of the tester.
PRO-D 3 may occur if there is battery leakage and it will void the warranty. 4. In the event the PRO-D 3 is not used for an extended period of time, the batteries should be removed. 5. Routinely clean the probe tip.
Page 18
3. The PRO-D 3 has been calibrated at the factory and should not require further calibration. If after using...