Mitsubishi Electric MXZ-SM36NAM2 Technical & Service Manual page 152

Split-type, heat pump air conditioners, outdoor unit, hfc utilized r410a
Table of Contents

Advertisement

OPERATING PROCEDURE
15. Removing the reactor (DCL)
(1) Remove the service panel. (See Photo 1)
(2) Remove the top panel. (See Photo 1)
(3) Remove the electrical parts box (See photo 5)
(4) Remove 6 screws (4 x 10) for reactors to remove the reac-
tors. (See Figure 3)
16. Changing the fusible plug
See the following descriptions.
• Be careful not to expose the fusible plug to the braze torch
flame or transfer heat to it. (See Photo 16)
• The temperature of the fusibleplug must not become 140°F
(60°C) or more while working. Protect the fusible plug with a
wet cloth when necessary.
(The fusible plug breaks at 158°F [70°C]).
• Tighten the screw in 14 - 18 N·m* (11-13 lbf·ft) with 2
wrenches.
*1 N·m ≈ 10 kgf·cm
OCH810A
PHOTOS/FIGURES
Figure 3
Screws for
reactors
Photo 16
Fusible plug
152
Reactors

Hide quick links: