Download Print this page

Preparing The Machine - Toro Groundsmaster e3200 Installation Instructions Manual

Energy expansion kit traction unit
Hide thumbs Also See for Groundsmaster e3200:

Advertisement

1

Preparing the Machine

No Parts Required
Procedure
1.
Park the machine on a level surface.
2.
Ensure that the parking brake is engaged.
3.
Shut off the machine and remove the key.
4.
Turn the battery-disconnect switch to the O
position.
5.
Raise the hood.
6.
Use a digital multimeter to measure the voltage
across the positive and negative bus bars.
The voltage should be less than 1 VDC. If
the voltage is above 1 VDC, ensure that
the key switch is in the Off position and the
battery-disconnect switch is in the Off position,
then check the voltage again. If the voltage is
still above 1 VDC, there may be a battery fault;
refer to the traction unit Service Manual or your
authorized Toro distributor.
2
Removing the Battery
Spacers and Bus Bars
No Parts Required
Procedure
Retain all removed parts for later installation.
1.
Remove the channel support and foam pad
from the battery compartment that contains 4
batteries
(Figure
1).
FF
1. Foam pad
2. Nut
2.
Remove the wire harness from the battery
spacers and the batteries
1. Wire-harness
connection—batteries
2. Wire-harness
connection—spacers
3.
Remove the battery spacers
battery compartment.
2
Figure 1
3. Channel support
(Figure
2).
Figure 2
3. Battery spacers
(Figure
2) from the
g448862
g448873

Advertisement

loading