Electrical connection
• Power: 100-240V, 50-60 Hz
• Maximum consumption: 3 A at 230 volts
Connect the platform to the mains with the attached power cable.
The cable can be used both indoors and outdoors.
• Brown wire: Phase wire
• Blue wire: Neutral wire
• Green/yellow wire: Earth wire
Important!
For safety reasons, the lifting platform must always be connected to earth.
Troubleshooting
No electrical functions.
The emergency stop button has been pressed. Turn the emergency stop button to the right.
The fuse is broken.
Replace the fuse or reset the RCD.
The lifting platform does not go down
Check that the upper level door is properly closed. Foreign objects are under the platform,
pinch protection has been activated. Clean under the platform from debris/snow etc.
Lamp (ALARM) lit on the panel
Remove part of the load from the platform, observing the maximum load specified for the
platform 350 kg.
The lifting platform does not go up
Check that the door on the lower level is properly closed.