netsys NV-520G User Manual

Industrial 4 giga lan over vdsl2 extender with dip switch

Advertisement

Quick Links

I I
n n
d d
u u
s s
t t
r r
i i
a a
l l
4 4
G G
I
n
d
u
s
t
r
i
a
l
4
G
U U
S S
U
S
N N
V V
- -
5 5
2 2
0 0
G G
N
V
-
5
2
0
G
i i
g g
a a
L L
A A
N N
O O
v v
e e
r r
i
g
a
L
A
N
O
v
e
r
w w
i i
t t
h h
D D
I I
P P
S S
w w
i i
w
i
t
h
D
I
P
S
w
i
E E
R R
' '
S S
M M
A A
N N
E
R
'
S
M
A
N
V V
D D
S S
L L
2 2
E E
x x
t t
e e
n n
V
D
S
L
2
E
x
t
e
n
t t
c c
h h
t
c
h
U U
A A
L L
U
A
L
d d
e e
r r
d
e
r

Advertisement

Table of Contents
loading

Summary of Contents for netsys NV-520G

  • Page 1 ’ ’ ’...
  • Page 2: Copyright

    In the interest of improving internal design, operational function, and/or reliability, NETSYS reserves the right to make changes to the products described in this document without notice. NETSYS does not assume any liability that may occur due to the use or application of the product(s) or circuit layout(s) described herein.
  • Page 3: Foreword: Vdsl2 For Industrial-Grade Solution

    Conditions and Safety Warnings. Netsys' NV-520G is a VDSL2 line port over 4 x Giga Ethernet ports that provide an economical solution for your industrial applications. Compliant with ITU-T G.993.2 VDSL2 standard, the NV-520G supports a maximum bandwidth of up to 160Mbps symmetric in VDSL2 Profile (35b) solution.
  • Page 4: Safety Warnings

     Use ONLY the dedicated power supply for your device. Connect the power to the right supply voltage (110V AC used for North America and 230V AC used for Europe. NV-520G supports 15 to 48 VDC dual power input (Redundant power)).
  • Page 5: Table Of Contents

    NV-520G Industrial grade LAN Extender USER’S MANUAL Rev. A.4 TABLE OF CONTENTS COPYRIGHT ................................ 1 FOREWORD: VDSL2 FOR INDUSTRIAL-GRADE SOLUTION ................2 SAFETY WARNINGS ............................3 CHAPTER 1. UNPACKING INFORMATION ......................6 1.1 Check List ...................................... 6 CHAPTER 2. INSTALLING NV-520G ........................7 2.1 Hardware Installation ..................................
  • Page 6 NV-520G Industrial grade LAN Extender USER’S MANUAL Rev. A.4 2.7 Industrial NV-520G Application ..............................13 CHAPTER 3. HARDWARE DESCRIPTION ......................15 3.1 Front Panel ....................................16 3.2 Front Indicators .................................... 21 3.3 Rear Panel ....................................22 3.4 Side Panel ....................................22 APPENDIX A: CABLE REQUIREMENTS ......................
  • Page 7: Chapter 1. Unpacking Information

    NV-520G Industrial grade LAN Extender USER’S MANUAL Rev. A.4 CHAPTER 1. UNPACKING INFORMATION 1.1 Check List Carefully unpack the package and check its contents against the checklist. Package Contents: 1 x NV-520G device 1 x QR code for user’s Accessory Kit : 1 x DIN-Rail mounting plate, 2 x screws, 4 x manual hyperlink.
  • Page 8: Chapter 2. Installing Nv-520G

    Verify the following installation requirements:  Power requirements: DC 15 to 48VDC redundant power.  The NV-520G should be located in a cool dry place, with at least 10cm/4in of space at the front and back for ventilation.
  • Page 9: General Rules

    We do not recommend the use of the telephone line 28 gauge or above. The RJ-11 connectors have six positions, two of which are wired. The NV-520G uses the center two pins. The pin out assignment for these connectors is presented below.
  • Page 10: Connecting Nv-520G

    Use any of the Ethernet ports to connect networking devices such as Monitor systems, Servers, Ethernet Switches. Notes: 1. The (RJ11/Terminal Block) Line port is used to connect the telephone that is connected to both NV-520G between CO and CPE mode (Point-to-point solution).
  • Page 11: Terminal Block And Din-Rail Mount Installation

    2.5 Terminal Block and DIN-Rail mount installation This section describes how to install the Terminal Block and DIN-Rail to the NV-520G, if you do not install the DIN-Rail, please paste the 4 rubber feet at the bottom of the hulled to avoid scratches of metal housing.
  • Page 12: Connecting The Rj-11 / Rj-45 Ports

     The line port has 2 connectors: RJ-45 and terminal block. It is used to connect from NV-520G (CO) over single pair phone cable to NV-520G (CPE) line port (point to point solution). Take note that NV-520G line port cannot be used at the same time. Either...
  • Page 13 Be sure each twisted-pair cable (RJ-45 Ethernet cable) does not exceed 100 meters (333 feet). We advise using Category 5~7 UTP/STP cables for making Networking device or NV-520G connections to avoid any confusion or inconvenience in the future when you attach high bandwidth devices.
  • Page 14: Industrial Nv-520G Application

    2.7 Industrial NV-520G Application NV-520G’s line port supports 100Mbps for data service across existing phone wiring. It is easy-to-use which do not require installation of additional wiring. Every modular phone jack in the home can become a port on the LAN. Networking devices can be...
  • Page 15 NV-520G Industrial grade LAN Extender USER’S MANUAL Rev. A.4 Figure 2.7 NV-520G industrial-grade application...
  • Page 16: Chapter 3. Hardware Description

    NV-520G Industrial grade LAN Extender USER’S MANUAL Rev. A.4 Chapter 3. Hardware Description The front panel provides a simple interface monitoring of NV-520G. It features the front panel, side panel and rear panel. NV-520G Outward...
  • Page 17: Front Panel

    NV-520G Industrial grade LAN Extender USER’S MANUAL Rev. A.4 3.1 Front Panel The figure shows the front panel. (Figure 3.1) Figure 3.1 Front Panel Tip: At a quick glance of the front panel, it is easy to tell if it has Ethernet signal from its RJ-45 port and if there is vdsl line signal on RJ-11 port.
  • Page 18 NV-520G Industrial grade LAN Extender USER’S MANUAL Rev. A.4 Figure 3.2 DIP switch setting...
  • Page 19 NV-520G Industrial grade LAN Extender USER’S MANUAL Rev. A.4  NV-520G function config over DIP Switch. (shown in Table 3-2) Configuration Table 3-2 DIP Switch on rear panel Config Mode Description PIN1 PIN2 PIN3 PIN4 Symmetric Auto, Max. Interleave=8, Min.Inp=2,...
  • Page 20 If during transit more than a certain amount of data has been lost then the data cannot be correctly decoded. Short bursts of noise on the line can cause these data packets to become corrupt and NV-520G has to re-request data which in turn can slow down the overall rate at which data is transmitted.
  • Page 21 NV-520G Industrial grade LAN Extender USER’S MANUAL Rev. A.4 unable to recover. By increasing the interleave depth of each port that are susceptible to noise, this will improve error performance and stability of marginal lines. INP(Impulse Noise Protection): Impulse noise in multicarrier communication systems behaves effectively as a modulating signal that controls the first moment of the background Gaussian noise.
  • Page 22: Front Indicators

    Note: Two of NV-520G connection may take within 3 minutes is normal, due to NV-520G to establish a link mechanism is auto-negotiation, with detects and calculate CO and CPE both PBO and PSD level as well as noise level ..and other argument etc.
  • Page 23: Rear Panel

    NV-520G Industrial grade LAN Extender USER’S MANUAL Rev. A.4 3.3 Rear Panel The following figure shows the rear panel. (Figure 3.3) Figure 3.3 Rear Panel Note: Please refer to section 2.5 to install the DIN RAIL. 3.4 Side Panel The following figure shows the side.
  • Page 24 Wiring the dual Power Inputs The NV-520G support two sets of power inputs, power 1 and power 2, which are located on NV-520G’s side panel. Power 1 is the bottom two contacts on the upper 6-contact terminal block and power 2 is the top two contacts on the lower 2-contact terminal block.
  • Page 25 1. State 1 always happens before state 2. 2. Protection means enable Reverse Polarity Protection function. 3. Please note that if use different DC voltage, higher voltage will feed to NV-520G first. 4. Please note that the warranty is void if DC 48V power input is exceeded.
  • Page 26 Wiring the Relay Contact NV-520G has a set of relay outputs. The relay contact uses of the terminal block’s contacts located on NV-520G’s side panel. Refer to the following table shows how to connect the wires to the terminal block connector. In this section, we illustrate the meaning of the two contacts used to connect the relay contact.
  • Page 27 Grounding the NV-520G NV-520G is designed to enhance EMS performance by grounding. NV-520G comes with metal DIN-Rail brackets for grounding the switches. For optimal EMS performance, connection of the right of the NV-520G side panel ground lug to the grounding point. Note: Please connect the ground lug to the earth to prevent electric shock, when the user touches.
  • Page 28: Appendix A: Cable Requirements

    NV-520G Industrial grade LAN Extender USER’S MANUAL Rev. A.4 Appendix A: Cable Requirements Ethernet Cable A CAT 5~7 UTP (unshielded twisted pair) cable is typically used to connect the Ethernet device to the Modem. A: 10/100TX cable often consists of four pairs of wires, two of which are used for transmission. The connector at the end of the 10/100TX cable is referred to as a RJ-45 connector and it consists of eight pins.
  • Page 29 NV-520G Industrial grade LAN Extender USER’S MANUAL Rev. A.4 Figure A-2 Pin Assignments and Wiring for an RJ-45 Straight-Through Cable Figure A-3 Pin Assignments and Wiring for an RJ-45 Crossover Cable...
  • Page 30: Appendix B: Product Specification

    NV-520G Industrial grade LAN Extender USER’S MANUAL Rev. A.4 Appendix B: Product Specification Key Features & Benefits  Supports high bandwidth up to 160Mbps symmetric over Line ports  Supports 4 x 10/100/1000M Ethernet ports  Supports RJ11/Terminal block combo line port ...
  • Page 31 NV-520G Industrial grade LAN Extender USER’S MANUAL Rev. A.4 Product Specification IEEE802.3/802.3u/802.3ab Ethernet standard Standard: G993.2 VDSL2 standard 4 * RJ-45 10/100/1000Mbps Ethernet port 1 * RJ-11/Terminal Block connector for VDSL2 line port Physical Interface: 1 * DIP Switch 1 * removable 6-contact terminal blocks for power1 and alarm contact...
  • Page 32 NV-520G Industrial grade LAN Extender USER’S MANUAL Rev. A.4 Fanless, free air cooling Storage Temperature: -40°C ~ 70°C (-40°F ~158°F) 5% to 95% (non-condensing) Humidity: Weight: 0.63 kg Dimensions: 171 x 121 x 35 mm ( 6.7" x 4.76" x 1.37”)
  • Page 33: Appendix C: Troubleshooting

    Appendix C: Troubleshooting Diagnosing NV-520G’s Indicators NV-520G can be easily monitored through its comprehensive panel indicators. These indicators assist the network manager in identifying problems the hub may encounter. This section describes common problems you may encounter and possible solutions.
  • Page 34 VDSL setting failure or phone cable length is over the specification limit. 3.1 Please make sure that the phone wire must be connected between NV-520G (CO) and NV-520G (CPE) when both are power on. NV-520G (CO) will do auto speed function depending on phone wire length and quality, therefore if NV-520G (CO) can’t detect NV-520G (CPE) over...
  • Page 35 NV-520G Industrial grade LAN Extender USER’S MANUAL Rev. A.4 The protocol was standardized in the International Telecommunication Union telecommunications sector (ITU-T) as Recommendation G.993.2. It was announced as finalized on 27 May 2005,[1] and first published on 17 February 2006. Several corrections and amendments were published in 2007 through 2011.
  • Page 36 NV-520G Industrial grade LAN Extender USER’S MANUAL Rev. A.4 SNR is commonly quoted for electrical signals, it can be applied to any form of signal (such as isotope levels in an ice core or biochemical signaling between cells). The ratio is usually measured...
  • Page 37 NV-520G Industrial grade LAN Extender USER’S MANUAL Rev. A.4 System Diagnostics Power and Cooling Problems If the POWER indicator does not turn on when the power cord is plugged in, you may have a problem with the power outlet, power cord, or internal power supply as explained in the previous section. However, if the unit power is off after running for a while, check for loose power connections, power losses or surges at the power outlet.
  • Page 38 NV-520G Industrial grade LAN Extender USER’S MANUAL Rev. A.4 Physical Configuration If problems occur after altering the network configuration, restore the original connections, and try to track the problem down by implementing the new changes, one step at a time. Ensure that cable distances and other physical aspects of the installation do not exceed recommendations.
  • Page 39: Appendix D: Ip-30 Protection Of Metal Case

    NV-520G Industrial grade LAN Extender USER’S MANUAL Rev. A.4 Appendix D: IP-30 protection of metal case The term “protection class” generally indicates the type of protection of a device or the internal workings of a device against direct contact and against the infiltration of foreign bodies, such as objects, dust or water.
  • Page 40 NV-520G Industrial grade LAN Extender USER’S MANUAL Rev. A.4 Table D-2 Second Digit: Protection grades for water protection. Digit Designation Explanation No protection No special protection to prevent water infiltration. Protection against vertically dripping Water dripping vertically on to the device may not have any harmful effect.
  • Page 41: Appendix E: Compliance Information

    NV-520G Industrial grade LAN Extender USER’S MANUAL Rev. A.4 Appendix E: Compliance Information FCC Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a computing device, pursuant to Part 15 of FCC rules.
  • Page 42 NV-520G Industrial grade LAN Extender USER’S MANUAL Rev. A.4 proper functioning of your equipment. If they do, you will be notified in advance in order for you to make necessary modifications to maintain uninterrupted service. This equipment may not be used on coin service provided by the telephone company. Connection to party lines is subject to state tariffs.
  • Page 43 NV-520G Industrial grade LAN Extender USER’S MANUAL Rev. A.4 RoHS Mark Warning RoHS stands for Restriction of Hazardous Substances, and impacts the entire electronics industry and many electrical products as well. The original RoHS, also known as Directive 2002/95/EC, originated in the European Union in 2002 and restricts the use of six hazardous materials found in electrical and electronic products.
  • Page 44: Warranty

    NV-520G Industrial grade LAN Extender USER’S MANUAL Rev. A.4 Warranty The original owner that the product delivered in this package will be free from defects in material and workmanship for one year parts after purchase. There will be a minimal charge to replace consumable components, such as fuses, power transformers, and mechanical cooling devices.
  • Page 45: Chinese Sj/T 11364-2014

    NV-520G Industrial grade LAN Extender USER’S MANUAL Rev. A.4 Chinese SJ/T 11364-2014 有 毒 有 害 物 质 或 元 素 部件名称 铅(Pb) 汞(Hg) 镉(Cd) 六价铬[Cr(VI)] 多溴联苯(PBB) 多溴二苯醚(PBDE) 结构壳体 ○ ○ ○ ○ ○ ○ 电路组 ○ ○ ○ ○...

Table of Contents