Advertisement

Quick Links

MELRemo
Smartphone application
(for users)
Applicable to PAR-CT0* series, PAC-SF0*CR, and PAR-4*MA series
remote controllers
• MELRemo (hereafter referred to
as the Application) is an application
software that can operate the
remote controllers for MITSUBISHI
ELECTRIC air conditioning systems
on a smartphone via Bluetooth
communication.
• The costs associated with
downloading and updating
the Application, and costs of
telecommunication to use the
Application (including the additional
costs of telecommunication for
reconfiguring the settings when the
Application is not properly updated or
operated) are the responsibility of the
user.
Contents
1. Safety precautions ..............................................................2
2. Basic operations .................................................................4
2-1. Remote controller selection ...................................................4
2-2. Power ON/OFF .....................................................................6
ventilation, louver, and HOLD settings ..................................6
2-3-1. Preset temperature setting .........................................7
2-3-2. Operation mode setting ..............................................8
2-3-3. Fan speed setting .......................................................8
2-3-4. Vane angle setting ......................................................9
2-3-5. Ventilation setting ........................................................9
2-3-6. Louver setting ...........................................................10
2-3-7. HOLD setting ............................................................10
3. Specifications .................................................................... 11
3-1. Applicable remote controllers .............................................. 11
3-2. Applicable smartphones ...................................................... 11
5. Trademarks .......................................................................14
WT08805X01
Instruction Book

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric MELRemo PAR-CT0 Series

  • Page 1: Table Of Contents

    WT08805X01 MELRemo Smartphone application (for users) Applicable to PAR-CT0* series, PAC-SF0*CR, and PAR-4*MA series remote controllers Instruction Book Contents 1. Safety precautions ..............2 2. Basic operations ..............4 2-1. Remote controller selection ...........4 2-2. Power ON/OFF ..............6 2-3. Temperature, operation mode, fan speed, vane angle, ventilation, louver, and HOLD settings ........6 2-3-1.
  • Page 2: Safety Precautions

    1. Safety precautions • Thoroughly read the following safety precautions before using the remote controller. • Observe these precautions carefully to ensure safety. WARNING Indicates a risk of death or serious injury. CAUTION Indicates a risk of serious injury or structural damage. • After reading this manual, pass it on to the end user to retain for future reference.
  • Page 3 Precautions for using smartphone application • When operating an air conditioner from a remote controller located outside the visibility of the air conditioner, make sure that the operation of the air conditioner will not negatively affect its surroundings or the occupants beforehand.
  • Page 4: Basic Operations

    2. Basic operations • Using the Application, air conditioning systems can be operated. • The following settings can be confi gured with the Application: ON/OFF, preset temperature, operation mode, fan speed, vane angle, ventilation, louver, and HOLD* settings *HOLD setting is displayed only when PAR-CT01MAU is connected. Note: T he setting cannot be changed for the function whose operation is prohibited or locked from the centralized controller or the remote controller.
  • Page 5 *1 The password can be displayed as follows. • PAR-CT0*MA series and PAC-SF0*CR → Tap [ ] at the top right corner of the Main display on the remote controller to display the password. • PAR-4*MA series → Press the F1 and F2 buttons simultaneously when ON/OFF is set to OFF on the Main display.
  • Page 6: Power On/Off

    2-2. Power ON/OFF (1) Tap the [ ] button to turn on or ON/OFF operation Error display off the air conditioner. Note: I f an error code (4-digit or 8-digit) appears on the screen, check the error code and troubleshoot accordingly, referring to the “Error code and troubleshooting table”...
  • Page 7: Preset Temperature Setting

    [2] How to change the setting (1) Tap the [ ] or [ ] button to change the setting. 2-3-1. Preset temperature setting • The preset temperature can be changed when the operation mode is Cool, Dry, Heat, or Auto (dual set point mode or Setback mode). Cool, Dry, Heat, Auto (dual set point or Setback) mode or Auto mode...
  • Page 8: Operation Mode Setting

    2-3-2. Operation mode setting • Operation mode can be changed. Cool Auto Heat Setback *1 Setback mode can be set only when PAR-CT01MAU is connected. 2-3-3. Fan speed setting • Fan speed can be set. Auto WT08805X01...
  • Page 9: Vane Angle Setting

    2-3-4. Vane angle setting • Vane angle can be set. Auto Auto Step 1 Step 2 Step 3 Step 4 Step 5 Swing Swing Note: T he icon may appear when the vane angle is set to Step 2, 3, 4, or 5 during cooling or dry operation.
  • Page 10: Louver Setting

    2-3-6. Louver setting • Louver can be turned on or off. 2-3-7. HOLD setting *HOLD setting is available only when PAR-CT01MAU is connected. • Tap the HOLD button to enable/disable the HOLD function. If the HOLD function is enabled, the following functions will be prohibited. •...
  • Page 11: Specifications

    3. Specifications 3-1. Applicable remote controllers Model name PAC-SF01CR PAR-CT01MAA-PB/SB PAR-CT01MAR-PB/SB PAR-CT01MAC-PB PAR-CT01MAU-SB PAR-40MA PAR-40MAAC 3-2. Applicable smartphones • Operating system requirement: iPhone iOS 10.0.0 or later WT08805X01...
  • Page 12: Q&A

    4. Q&A [1] The remote controller to be connected is not displayed on the remote controller selection screen. • Check that the Bluetooth is ON on the remote controller and the Application, and then restart the Application. [2] An error is displayed. •...
  • Page 13 Error code Error definitions Error contents Action to take 8207–7900 Operation error The remote controller Wait for the system to start is operated from the up, and then connect the Application while the Application and the remote air conditioning system controller again. is being started up.
  • Page 14: Trademarks

    • The word Bluetooth and its logo mark are trademarks of Bluetooth ® SIG, Inc., and Mitsubishi Electric Corporation is granted the right to use these trademarks. Other trademarks and trade names are properties of their respective companies. WT08805X01...
  • Page 15 HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN MANUFACTURER: M ITSUBISHI ELECTRIC CORPORATION Air-conditioning & Refrigeration Systems Works 5-66, Tebira 6 Chome, Wakayama-city, 640-8686, Japan WT08805X01...

This manual is also suitable for:

Melremo pac-sf0 cr seriesMelremo par-4 ma series

Table of Contents