10) Room temperature sensor switching (Aux.)
To use the temperature sensor on the wired remote controller only, change the setting to "Wired remote controller" (01).
This function will only work if the function setting 42 is set at "Both" (01)
Setting Description
Both.
Wired remote controller
11) Indoor unit fan control for energy saving for cooling
Enables or disables the power-saving function by controlling the indoor unit fan rotation when the outdoor unit is stopped during cooling
operation.
Setting Description
Disable
Enable
00: When the outdoor unit is stopped, the indoor unit fan operates continuously following the setting on the remote controller.
01: When the outdoor unit is stopped, the indoor unit fan operates intermittently at a very low speed.
( . . .Factory setting)
Function Number
Setting Value
00
48
01
( . . .Factory setting)
Function Number
Setting Value
00
49
01
- (01 - 28) -