1-2 Major Component Specifications
KPAF128C5TAA
Controller PCB
Part No.
Controls
Control circuit fuse
Jumper setting JP1..JP5
Remote Control Unit
Fan & Fan Motor
Type
Q'ty ....... Dia. and lenght
Fan motor model...Q'ty
No. of poles...rpm (230 V, High)
Nominal output
Running Amps
Power input
Coil resistance (Ambient temp. 25 °C )
Safety devices
Run capacitor
Flap Motor
Type
Model
Rating
Coil resistance (Ambient temp. 25 °C )
Heat Exch. Coil
Coil
Rows
Fin pitch
face area
Type
Operating temp. Open
Close
mm
W
A
W
Ω
°C
µF
VAC
Ω
Aluminium plate fin / Copper tube
mm
2
m
DATA SUBJECT TO CHANGE WITHOUT NOTICE
7
SAC ON-OFF IDU
Microprocessor
250 V - 3,15 A
2,54mm-5pcs
SAC W-REM
Cross - flow
2.... Ø 130 / L 180
K48407-M01596...1
4...1160
21
0,29
65
GRY-WHT: 298÷343
WHT-PNK: 421÷485
WHT-VLT: 93,5÷108
VLT-ORG: 93,5÷108
ORG-YEL: 211÷243
Thermal protection
145 ± 5
Automatic
1.5
440
Stepping motor
MP24Z2
DC 12 V
400 ± 7%
2
1,5
0,177