B Check of remote controller and indoor electronic control P.C. board
NOTE: Check if the remote controller is exclusive for this air conditioner.
Press OFF/ON (stop/operate) but-
ton on the remote controller.
Is LCD display on the remote
controller visible?
Yes
Remove the batteries, then set them
back and press RESET button.
(Refer to 10-1.4.)
Check if the unit operates with the
remote controller.
Does the unit operate with the
remote controller?
Yes
OK
OBH766G
Replace the batteries. (Refer to 10-1.4.)
No
(Not clear)
Assign a number of remote controller.
(Refer to 8-2.)
Check if the unit operates with the
No
remote controller.
Does the unit operate with
the remote controller?
Yes
OK
Measure the voltage between display and receiver P.C. board connector CN301 No.1(-)
and No.2(+) when the remote controller button is pressed.
Is the voltage approximately 4 V DC - 5 V DC?
Replace the display and receiver P.C. board.
*
1 Look at the image of the signal transmitting section of
the remote controller through the monitor of a digital
camera or a camera phone. It is normal if the LED
of the signal transmitting section lights up when the
OFF/ON (stop/operate) button on the remote control-
ler is pressed. However, it may be difficult to see the
illuminated LED of the signal transmitting section with a
smartphone camera.
* 2 If the inverter fluorescent light is turned on when the
room is cool, the unit may have difficulty receiving the
signal from the remote controller or may not be able to
operate with it; if the inverter fluorescent light is turned
on when the room is warm, the unit may be able to
operate with the remote controller.
Turn ON a radio to AM and press
OFF/ON (stop/operate) button on
No
the remote controller. *1
Is noise heard from radio?
Yes
Are there any fluorescent lights
of inverter or rapid-start type
within the range of 1 m? *2
No
Yes
No
47
Replace the remote controller.
No
• Reinstall the unit away from lights.
• Attach a filter on receiving part.
Yes
Replace the indoor electronic
control P.C. board.