Fault
Appliance paused, but
the drum is rotating.
Creasing.
and programme
terminated.
Condensation in the
condensation tank
even though the water
drain hose is connec-
ted.
Cause and troubleshooting
Cooling process active.
Not a fault – no action required.
The load is too large.
Observe the maximum load capacity of the
→ "Programmes", Page 26.
The laundry lies in the drum for too long after drying.
Remove the laundry from the drum as soon as the
1.
drying programme has finished.
Spread the items of laundry for cooling.
2.
Unsuitable programme for the type of fabric.
Set the suitable programme for the type of fabric.
→ "Programmes", Page 26
Easy-Care fabrics are dried for too long.
→ "Changing the dryness level", Page 25.
→ "Adjusting the dryness level", Page 25.
Anti-Crease not activated.
Activate the Anti-Crease function.
→ "Buttons", Page 23
Condensation tank filled.
→ "Emptying the condensation container", Page 32.
1.
→ "Inserting the condensation container", Page 32.
2.
→ "Starting the programme", Page 29.
3.
Water drain hose is caught or jammed.
Ensure that the water drain hose is not kinked or
1.
trapped.
Route the water drain hose without kinks.
2.
Water drain hose is not connected correctly.
Ensure that the water drain hose is connected cor-
rectly.
→ "Connecting the water drain hose", Page 14
Water drain hose is blocked.
Rinse the water drain hose with tap water.
The filter for the condensation tank is soiled.
→ "Clean the filter for the condensation tank.",
Page 39.
The appliance uses condensation for the automatic
self-cleaning.
Not a fault – no action required.
Water drain hose is not connected correctly.
Troubleshooting en