TOGGLE AUTO PARK (ON/OFF)
Dome cameras can be set to automatically move to preset position No. 1 after a set
2XX
stopping interval passes.
XX = 01 – 99(*): Waiting time (minutes) before automatically stopping
(*) when waiting time XX=00, the function is invalid.
Example:
"205" Automatically stop after waiting for 5 minutes (XX=05)
"200" Automatic stop OFF (XX=00)
TOGGLE AUTO PATROL (ON/OFF)
Dome cameras can be set to automatically start the specified patrol order after a set
1XXY
stopping time passes.
XX = 01 – 99(*): Waiting time (minutes) before automatic patrolling.
Y = 0 – 5: Patrol number
(*) when waiting time XX=00, the function is invalid.
Example:
"1153" After stopping for 15 minutes (XX=15), automatically patrols in No. 3 (Y=3)
patrol order.
"1003" Automatic patrol OFF (XX=00)
OTHERS
Patrols all positions
0
Switches automatic U-turn (ON/OFF).
1
Aux 1 ON
2
Aux 1 OFF
3
Installed alarm: ON
7
Installed alarm: OFF
8
U-turn
10