Diamond DANNY PLUS Technical Instructions

Serve-over counter

Advertisement

Mod: DANNY PLUS
Code Fabricant
DY100PSVG17HQ
DY120PSVG17HQ
DY150PSVG17HQ
DY180BSVG17HQ
DY100PSVG08HQ
DY120PSVG08HQ
DY150PSVG08HQ
DY180BSVG08HQ
DY100PSVG13HQ
DY120PSVG13HQ
DY150PSVG13HQ
DY180BSVG13HQ
10/2021
Ref. Diamond
DY10/A1-R2
DY12/A1-R2
DY15/A1-R2
DY18/A1
DY10/B1-R2
DY12/B1-R2
DY15/B1-R2
DY18/B1
DY10/C1-R2
DY12/C1-R2
DY15/C1-R2
DY18/C1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DANNY PLUS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Diamond DANNY PLUS

  • Page 1 10/2021 Mod: DANNY PLUS Code Fabricant Ref. Diamond DY10/A1-R2 DY100PSVG17HQ DY12/A1-R2 DY120PSVG17HQ DY15/A1-R2 DY150PSVG17HQ DY18/A1 DY180BSVG17HQ DY10/B1-R2 DY100PSVG08HQ DY12/B1-R2 DY120PSVG08HQ DY15/B1-R2 DY150PSVG08HQ DY18/B1 DY180BSVG08HQ DY10/C1-R2 DY100PSVG13HQ DY12/C1-R2 DY120PSVG13HQ DY15/C1-R2 DY150PSVG13HQ DY18/C1 DY180BSVG13HQ...
  • Page 2 Te c h n i c a l i n s t r u c t i o n s SERVE-OVER COUNTER...
  • Page 3 - to expose the equipment to the atmospheric agents (sun, snow, rain, etc.); - to wash the equipment with water jets; - to allow children to use the equipment without adult supervision and make sure that they do not play with the equipment;...
  • Page 4: Handling And Transport

    maintenance personnel and generally to all the pe- 4. UNPACKING ople that for different reasons have to operate with the equipment. The packing materials can be recycled, therefore they must not be dispersed, but they have to be disposed in the special waste plan for recycling.
  • Page 5: Installation

    the exchange of air in the environment even when the room is closed: Max. allowed ambient R.H. Max allowed relative temperature humidity +25°C During the installation procedure, it is prohibited to: In case the ambient conditions are not included in - Tilt the cabinet, as the lubricating oil contained in the above mentioned ones, a lower performance the cabinet itself could enter the cold circuit and the...
  • Page 6 be assembled by qualified people after the equip- - The cable of the equipment should be checked re- ment has been positioned on its place. The assem- gularly. If it should result that the cable is damaged bling instructions are contained in the envelope that or deteriorated, disconnect the equipment and do is supplied inside the packing.
  • Page 7 13. LOADING INDICATIONS - the equipment is positioned in an ambient with higher temperature or relative humidity than above indicated - the amount of displayed goods exceeds the maximum This refrigerated cabinet is proper for the preservation of recommended and the proper air circulation is prevented. foodstuffs if the following rules are respected: In those cases the goods are kept at higher temperatures, a) arrange the goods in the space provided in such a...
  • Page 8: Emergency Situations

    display surface, the shelves, the glasses with specific proceed as indicated at paragraph 16); cleaners for any surface. - if the condenser is clean (paragraph 18); - if there are air draughts, if the cabinet is installed in the correct position (see paragraph 9) and if the Do not use acid and alkaline detergents, chemical ambient temperature is as indicated (see paragraph / organic solvents, unknown chemical composition...
  • Page 9 Keep the counter away from free fl ames or sources of ignition. IN CASE OF DAMAGE Keep the counter away from free fl ames or sources of ignition Thoroughly ventilate the area for a few minutes. Swi- tch off the counter and disconnect the power plug. Contact customer service.