Marus Nustar 1700 SII Series Owner's Manual

Marus Nustar 1700 SII Series Owner's Manual

Hydraulic chairs

Advertisement

Quick Links

Nustar 1700 SII Series
Hydraulic Chairs
OWNER'S MANUAL
Wide Back
Narrow Back
11727 Fruehauf Drive
Charlotte, NC 28273 USA
800-304-5332

Advertisement

Table of Contents
loading

Summary of Contents for Marus Nustar 1700 SII Series

  • Page 1 Nustar 1700 SII Series Hydraulic Chairs OWNER’S MANUAL Wide Back Narrow Back 11727 Fruehauf Drive Charlotte, NC 28273 USA 800-304-5332...
  • Page 2 Upholstery is warranted for a period of one year from the date of purchase. During that period, we will replace any defective part at no charge. Marus WILL NOT be responsible for dealer or service company labor charges or shipping charges to the Marus factory.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS General Information ..........................2 Definitions of Symbols ........................2 IEC Symbols ............................2 Equipment Disposal .........................2 Incompatible Equipment .........................2 Obtaining Technical Literature......................2 Interference with Electromedical Devices ..................2 Electrical Specifications ........................2 Safety Information ..........................3 Storage Conditions ..........................3 Regulatory Information ...........................4 Technical Description ........................4 Device Classification ........................4 Safety and Identification Markings ....................4 Cleaning, Disinfecting &...
  • Page 4: General Information

    GENERAL INFORMATION DEFINITION OF SYMBOLS PRODUCT DISPOSAL Contact your local authorized dealer for proper The following symbols and terms may be used disposal of the device to ensure compliance with your throughout this manual: local environmental regulations. WARNING: Failure to carefully follow the described procedure may result in damage INTERFERENCE WITH ELECTROMEDICAL DEVICES to the equipment and/or injury to the patient/...
  • Page 5: Safety Information

    SAFETY INFORMATION Review the following safety precautions to avoid injury and prevent damage to this equipment. Use this product only as specified. WARNING: WARNING: Failure to disinfect equipment A dental chair may include between patients could expose user/ magnets in the construction of the patient to cross contamination and bio- device which may temporarily affect burden/bio-contamination.
  • Page 6: Regulatory Information

    REGULATORY INFORMATION Technical Description The dental chair is used to position the patient so that the oral cavity is in the desired position for the dentist to perform various dental procedures. Dental chairs can be either hydraulically or electromechanically operated. There are two dynamic functions: the base (up/down) and the back (forward/back).
  • Page 7: Cleaning, Disinfecting & Sterilization

    CLEANING, DISINFECTING & STERILIzATION Equipment can be cleaned with a solution of mild detergent and warm water. A variety of surface disinfectants are available for use in dental treatment rooms. Some of these can cause discoloration of painted, plated or anodized surfaces with repeated use.
  • Page 8: Cleaning Upholstery

    CLEANING UPHOLSTERY* While staining and soiling exposures are common to upholstery fabrics, most may be removed by using the following cleaning methods. Light Soiling • Use a solution of 10% household liquid dish soap with warm water and apply with a soft, damp cloth.
  • Page 9: Chair Setup And Installation

    CHAIR SETUP AND INSTALLATION Before You Begin • Depending on the application, the chair’s • Study the overall dimensions of the chair shown below. Make sure the chair will have sufficient upholstery may or may not be installed at the clearance when in both the upper and lower factory.
  • Page 10: Chair Installation

    CHAIR INSTALLATION 1. Remove the carton lid and sides from the 3. Verify that the chair base is on a level surface pallet as well as the packing material. Using and does not rock due to high or low spots a 9/16”...
  • Page 11: Chair Control Functions

    CHAIR INSTALLATION (Cont’d) 7. Hook two (2) places onto the Handle seat rail as shown in figure 3. 8. Turn the handle to attach the front of the cushion to the seat rail. Hooks 9. This completes the installation procedure for the chair’s upholstery.
  • Page 12: Quick Release Double-Articulating Headrest

    CHAIR FUNCTIONS (Cont’d) Quick Release Double-Articulating Headrest The headrest is adjusted by pressing the large release button. This unlocks both articulating Release Button joints allowing the desired position to be set quickly and accurately. To set the height, simply Headrest pull the headrest upward, away from the chair Rotation 1/4-20 Button...
  • Page 13: Positioning For Wheelchair Patients

    CHAIR CONTROL FUNCTIONS (Cont’d) Positioning for Wheelchair Patients Your chair can easily be converted to accommodate wheelchair patients. Remove the headrest by pulling upward out of the chair back; reinstall the headrest in a reversed position as shown. Loosen the adjustment knob and adjust headrest into desired position.
  • Page 14: Touchpad Back Control

    Programming the “0” Position The exit or “0” position can be reprogrammed to the Learn Button desired position in the same manner as above. (under Marus logo) Position #1 (Press once to activate) Position #2 (Press once to activate)
  • Page 15: Electronic Foot Control

    CHAIR CONTROL FUNCTIONS (Cont’d) Electronic Foot Control The electronic foot control allows the user to control the chair’s manual base and back movement and access the automatic positions. Foot Control Operation and Programming Operating the Automatic Positions The “0” and “1” buttons access programmable operating positions, also shown below.
  • Page 16: Electromagnetic Compatibility

    ELECTROMAGNETIC COMPATIBILITY MEDICAL ELECTRICAL EQUIPMENT ELECTROMAGNETIC COMPATIBILITY (Instructions for use) ELECTROMAGNETIC COMPATIBILITY Electrical medical devices are subject to special EMC safety measurements and as a result the equipment must be installed according to the installation instruction manual. PORTABLE ELECTRONIC DEVICES Portable and mobile high frequency electronic communications equipment may interfere with electronic medical devices.
  • Page 17 ELECTROMAGNETIC COMPATIBILITY Guidance and manufacturer‘s declaration-electromagnetic immunity This product is intended for use in the electromagnetic environment specified below. The customer or the user of this product should ensure that it is used in such an environment. IMMUNITY TEST IEC60601 TEST LEVEL COMPLIANCE LEVEL ELECTROMAGNETIC ENVIRONMENT GUIDANCE...
  • Page 18 ELECTROMAGNETIC COMPATIBILITY Guidance and manufacturer's declaration-electromagnetic immunity This product is intended for use in the electromagnetic environment specified below. The customer or the user of this product should assure that it is used in such an environment. ELECTROMAGNETIC ENVIRONMENT Immunity Test IEC60601 Test Level Compliance Level GUIDANCE...
  • Page 19 ELECTROMAGNETIC COMPATIBILITY Guidance and manufacturer‘s declaration-electromagnetic emissions Guidance and manufacturer‘s declaration-electromagnetic emissions This product is intended for use in the electromagnetic environment specified This product is intended for use in the electromagnetic environment specified below. The customer or the user should assure that it is used in such an below.
  • Page 20: Checklist

    CHECkLIST Verify the following after installation or servicing of the chair: All manuals are present. All labels are present and legible. The chair is installed/assembled correctly and there is no mechanical damage on new installations. The chair can be moved and positioned freely without any drifting. The chair is connected to the appropriate power source.
  • Page 21 Purchase Information Write in the model and serial numbers below for all applicable equipment such as the chair, unit light and unit control head. MODEL: _______________________________ DATE PURCHASED: _____________________ SERIAL NUMBER: ______________________ DATE INSTALLED: ______________________ DEALER NAME AND ADDRESS: MODEL: _______________________________ ________________________________ SERIAL NUMBER: ______________________ ________________________________...
  • Page 22 11727 Fruehauf Drive Charlotte, NC 28273 Technical support: 800-304-5332 FAX: 888-861-9366 31064 • Rev. 00 • 02/04/14...

Table of Contents