Installation Notes; Installation Requirements; Environmental Requirements; Electrical Connection - Miele PFD 100 Installation Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 13
en - Installation notes
Installation re-
quirements
Environmental re-
quirements
Vapour barrier film
for built-in appli-
ances
Electrical connec-
tion
Plug connection
Hard-wired
Residual current
device (RCD)
Equipotential
bonding
14

Installation notes

For safe installation and commissioning of the dishwasher please
read the installation plan, the service documentation, the installa-
tion sheet and the operating instructions.
This installation plan includes the dimensions of the appliance, the
technical data and the requirements to be met on site for the installa-
tion of the dishwasher.
This dishwasher must only be installed and commissioned by the
Miele Customer Service Department, a Miele authorised dealer or a
suitably qualified specialist.
Installation should only be performed in accordance with valid reg-
ulations, relevant standards and health and safety codes.
Condensate can build up in the area surrounding the dishwasher. Any
furniture and fittings in the room must therefore be suitable for pur-
pose.
The vapour barrier film supplied protects the worktop from damage
caused by steam when the door is opened. Attach the vapour barrier
film above the door, underneath the worktop.
All work on the electrical connection must be carried out by the Miele
Customer Service Department, an authorised Miele dealer or a quali-
fied electrician.
The dishwasher should be connected to the electricity supply via a
socket.
If the dishwasher is hard-wired to the power supply, a power switch
capable of disconnecting the dishwasher at all poles must be in-
stalled on site. This power switch must have a contact gap of at least
3 mm.
The socket and the power switch must be accessible after the appli-
ance has been installed. An electrical safety test must be carried out
after installation and after any servicing work.
The mains connection cable must be laid protected from the risk of
thermal damage.
For increased safety, it is recommended to protect the dishwasher
with a residual current device (RCD) with a trip current of 30 mA.
There is a screw connection point for equipotential bonding at the
back of the dishwasher.
Equipotential bonding should be carried out if possible on site.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents