Replacing the main exchanger
Before carrying out the following instructions it is advisable to protect the room and the boiler's electrical box
A
against accidental water spillage.
3
1
Disconnect the power supply and close the gas cock ahead of the valve
Disconnect the fume sensor connector
Disconnect the fan connector
Disconnect the connector of the ignition electrode connected to the board.
Drain the water from the boiler heating circuit.
Extract the flue connection (concentric or accessory for separate ducts)
Remove the fan
Remove the clips of the two pipes on the exchanger, pump and hydraulic unit
Remove the 2 top screws "5" securing the exchanger to the frame (fig. 40)
Loosen the 2 bottom screws "5" securing the exchanger to the frame (fig. 40)
Remove the exchanger
Fit the new exchanger on the bottom screws "5"
For assembly, proceed in reverse order
EN
4
1
2
1
2
fig. 40- Main exchanger