1.
Installing the mounting plate.
• The mounting plate should be installed on a wall which can support the weight of the indoor unit.
1) Temporarily secure the mounting plate to the wall, make sure that the panel is completely level, and mark the boring
points on the wall.
2) Secure the mounting plate to the wall with screws.
Recommended mounting-plate retention spots and Dimensions
41.3
English
Recommended mounting - plate
retention spots (5 spots in all)
120.5
203
54.5
160
330.5
Keep here the piece cut out
from the unit for piping
* The removed pipe port cover can be
kept in the mounting plate pocket.
Place a leveler
on raised tab.
247
50
Gas pipe end
331
Liquid pipe end
770
Removed pipe
port cover
Use tape measure
as shown.
Position the end of
a tape measure at
.
101
41.3
160
54
Through-
the-wall
hole ø65mm
Drain hose
position
Mounting plate
5