Safety Precautions
• Do not install the air conditioner in a place where there is danger of exposure to inflammable gas leakage.
If the gas leaks and builds up around the unit, it may catch fire.
• Establish drain piping according to the instructions of this manual.
Inadequate piping may cause flooding.
• Tighten the flare nut according to the specified method such as with a torque wrench.
If the flare nut is tightened too hard, the flare nut may crack after a long time and cause refrigerant leakage.
• This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for
commercial and household use by lay persons.
• Sound pressure level is less than 70dB(A).
• Before obtaining access to terminal devices, all power supply circuits must be interrupted.
Accessories
,
Indoor unit
A
L
Mounting plate
A
Titanium apatite deodorizing
B
filter
Wireless remote controller
D

Choosing an Installation Site

• Before choosing the installation site, obtain user approval.
1.
Indoor unit.
• The indoor unit should be sited in a place where:
1) the restrictions on installation specified in the indoor unit installation drawings are met,
2) both air intake and exhaust have clear paths met,
3) the unit is not in the path of direct sunlight,
4)the unit is away from the source of heat or steam,
5)there is no source of machine oil vapour (this may shorten indoor unit life),
6) cool (warm) air is circulated throughout the room,
7) the unit is away from electronic ignition type fluorescent lamps (inverter or rapid start type) as they may shorten the
remote control range,
8) the unit is at least 1 metre away from any television or radio set (unit may cause interference with the picture or sound),
9) to avoid accidental touching, it is recommended to install the unit higher than 2,5m.
2.
Wireless remote controller.
1) Turn on all the fluorescent lamps in the room, if any, and find the site where remote control signals are properly received
by the indoor unit (within 7 metres).
2
CAUTION
1
Remote controller holder
E
2
AAA dry-cell batteries
G
Indoor unit fixing screws
H
1
(M4 × 12L)
1
Operation manual
K
2
Installation manual
L
2
1
1
English