Download Print this page

Yeswelder FP-5P-B Operator's Manual page 4

Foot pedal

Advertisement

Up To 20 Feet (6 m)
Up To 20 Feet (6 m)(GD Models)
21 To 100 Feet (6 to 30 m)(GD Models)
21To 50'Feet (6 to 15 m)
51 To 100 Feet (16 to 31 m)
101To 200 Feet (31 to 61 m)
*AWG -American Wire Gauge
3. REMOTE AMPERAGE
On most welding power sources or welding generators,
when a Remote Foot Control is used, the Remote Foot Con-
trol functions as a fine amperage adjustment of the Amper-
age on the welding power source or welding generator. For
example: If the Amperage Adjustment Control on the weld-
ing power source or welding generator is set at the mid-
point position, the Remote Foot Control provides (from its
minimum to maximum positions) fine adjustment of one half
of the welding power source or welding generator output. If
full adjustment of the maximum output of the welding power
source or welding generator from the Remote Foot Control
is desired, rotate the Amperage Adjustment Control on the
welding power source or welding generator to the maximum
position. On some welding power sources or welding gener-
ators the Amperage Adjustment Control is inoperative when
a Remote Foot Control is used.
Page 03
Table 2-1.Cord Length And Size
Amperage Control
Cord
Length
Contactor Control
Cord
Conductor
Length
size*
No.16
No.14
No.12
Up To 200
No.14
Feet (61m)
No.12
No.10
Conductor
Size
No.16

Advertisement

loading