DISASSEMBLY- AND RE-ASSEMBLY ADVISE
• To replace the parkhook (13), first remove Screw C,
then by pushing the two lips with a screwdriver the
parkhook can be removed (see picture).
• To replace the cordwinder (20), first remove the
wires, the locks can be unlocked with a screw driver
(see picture).

ELECTRICAL DIAGRAM

L
K
AC
220 - 240 V
50 Hz
N
C
ZD1
C2
4.7V
220F
½ W
16V
D1
C1
1N4007
0.47F
275V
R2
10k-1W
R4
10M-¼W
R1
10k-1W
• The safety valve assy (21) can be clogged with dust, it can
be easily taken out and replaced after the tophousing has
been removed, it must be done from inside the bottom
housing where the cordwinder is situated (see picture).
• When replacing the motor, make sure that the two red
wires are placed underneath the motor.
• To replace the caster assy (11), squeeze the 2 dividers
in the middle of the hole of the caster arm together
with pliers, at the same time pull the caster assy off
(see picture). The new caster assy can be snapped on in
one single move.
4
10
C3
22nF
7
9
U1
6
11
5
8
R3
10M-¼W
FC8454/01
R5
TR1
27-¼W
TMP
RW
47k
M
Motor