Upgrading The Firmware - Honeywell QuantumT MS3580 User Manual

Omnidirectional laser scanner
Table of Contents

Advertisement

U
PGRADING THE
The MS3580 is part of Honeywell's line of scanners with flash upgradeable
firmware. The upgrade process requires a new firmware file supplied to the
customer by a customer service representative

software
. A personal computer running Windows 95 or greater with an
available RS232 serial or USB port is also required to complete the upgrade.
PowerLink Cable #54-54014 is required when using RS232 for the
upgrade process. Do not use the standard cable supplied with
keyboard wedge or RS485 scanner interface kits. If using USB for the
upgrade process, the standard USB Type A cable provided with the
scanner can be used.
To upgrade the firmware in the MS3580:
1.
Plug the scanner into a serial communication port on the host system.
2.
Start the MetroSet2 software.
3.
Click on the plus sign (+) next to POS Scanners to expand the supported
scanner list.
4.
Choose the Quantum E/T from the list.
5.
Click on the Configure Quantum E/T Scanner button.
6.
Choose Flash Utility from the options list located on the left side of the
screen.
7.
Click on the Open File button in the Flash Utility window.
8.
Locate and open the flash upgrade file supplied by Honeywell.
9.
Select the COM port that the scanner is connected to on the host system.
10. Verify the settings listed in the Flash Utility window.
11. Click on the Flash Scanner button to begin the flash upgrade.
12. A message will appear on the screen when the upgrade is complete.
See Contact Information on page 53.

MetroSet2 is available for download, at no additional cost, from
www.honeywellaidc.com.
40
F
IRMWARE
and Honeywell's MetroSet2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Quantumt 3580

Table of Contents