HADEF 14/12-EX Installation, Operating And Maintenance Instruction page 7

Spur gear hoist
Table of Contents

Advertisement

DANGER!
Special safety measures for use in areas prone to explosion.
 No use in zone 0 or zone 20
 Not to be used with IIC gases and IIB gases hydrogen sulphide, ethylene oxide and light metal and shock
sensitive dusts!
 No use in temperature class T5 or T6.
 It is not allowed to use the equipment in area at risk from explosion where gas AND dust does both exist
at the same time!
 During assembly and operation of explosion-proof equipment, the relevant regulations of i.e. BG-Chemie
about the use of equipment in area at risk from explosion, must be adhered to by the user/owner.
 Please make sure that external ventilation is sufficient.
 Please wear conductive shoes. Gloves should have a shunt resistance of < 10
 It is not allowed to take off clothes.
 The surface temperature of the devices could increase by a variety of external circumstances. For this
reason, the surface temperature is to be monitored.
 Avoid ignitable dust deposits.
 Remove dust deposits daily before commencing work and ensure that dust cannot settle between moving
parts.
 Never remove dust with compressed air - remove it with a wet bolt of cloth.
 Defective units or units that show abrasion of its surface rust on chains, hooks, or suspension devices,
must be taken out of service.
 Please observe the prescribed intervals.
 Assembly and maintenance work must only be carried out in an atmosphere not prone to explosion.
 Check the grease level of the bearings regularly
 Exchange friction surfaces in time and (an exception to this are electric units - maintenance of the brakes
must only be effected by HADEF).
 Protect the device from impact, friction, rough handling and moisture.
DANGER!
The operator is responsible for professional equipotential bonding (earthing) for power-operated
devices!
Special scope
Use of different EX-zones is depended from the EX-classification of the unit. Find the EX-classification on its
type plate.
5.52.121.01.01.08
Unit classified
in EX-classification
3G
3D
2G
2D
.
8
No use
in EX-zone
0,20,1,21,22
0,20,1,21,2
0,20,21,22
0,20,1,2
7