6.Printed circuit board connector wiring diagram

Connectors
PCB(1) (Control PCB) For AS24TD2HRA
1) CN9 Connector for fan motor
2) CN6 Connector for heat exchanger thermistor and Room temperature thermistor
3) CN5 Connector for UP&DOWN STEP motor
4) CN11,CN10 Connector for L&R STEP motor
5) CN21 Connector for power N wire
6) CN52 Connector for power L
7) CN7 Connector for display board
8) C0N2,C0N3 Connector for ions generator
9) CN23 Connector for communicate between the indoor board and the outdoor board
10) CN36 Connector for long-range control
11) CN34 Connector for Net Module
12) CN51 Connector for room card
13) CON1 Connector for Fresh air
Note: Other designations
PCB(1) (Indoor Control PCB)
1) SW1 Connector for Forced operation ON / OFF switch
2) SW2 1 Select remote code A or B, 2 Select room card able or disable 3,4 Select 23 26 33 and
35 ,
3) RV1 Varistor0
4) FUSE1 Fuse 3.15A/250VAC