Vector TCY-MT2-W01 Instruction Manual

Pi-temperature controller

Advertisement

Quick Links

TCY-MT series PI-temperature controller
Features
Temperature PI control for HVAC systems.
Up to 2 modulating outputs for DC 0–10 V with 10 mV resolution.
1 internal temperature sensor and up to 2 external sensor inputs
Multiple remote control functions on external input
Password protected programmable user and control parameters
Blue backlight
Applications
Various temperature control applications
Stand alone VAV control for pressure independent actuators
Water-only systems: Radiator, floor heating or chilled ceilings
Individual room control for offices, residential, hotel rooms,
meeting rooms, etc.
General Description
The TCY-MT is a stand-alone electronic temperature controller with one
control loop. It may use up to 2 PI sequences. The TCY-MT features one internal NTC temperature sensor, up to two
external sensor inputs and up to two analog outputs. The configuration has been reduced to a minimum to allow for
simple and off-the-shelve usage. For more advanced features and current inputs and outputs the TCI product range is
recommended. The TCY-MT can be configured using the standard operation terminal. No special tool or software is
required.
Name
- M
T
C Y
T
2
Ordering
Item Name
Item code
TCY-MT2-W01
40-10 0043-01
TCY-MT2-W02
40-10 0043-02
TCY-MT2
40-10 0043
TCY-MT4
40-10 0045
Accessories
S-Tn10-2
40-20 0001
SD-Tn10-12-2
40-20 0002
SD-Tn10-20-2
40-20 0003
SDB-Tn10-12-1
40-20 0124
SDB-Tn10-20-1
40-20 0133
SOA-Tn10
40-20 0006
Selection of actuators and sensors
Temperature Sensors:
Use only our approved NTC sensors to achieve maximum accuracy. Recommended is SDB-Tn10-20 as Duct sensor, SRA-
Tn10 as Room sensor and SDB-Tn10-20 with AMI-S10 as immersion sensor.
Modulating Actuators:
Choose actuators with an input signal type of 0–10V DC or 2–10V DC.
Doc: 70-00-0058 V1.2, 20160322
Subject to alteration
-
(
)
U
Housing:
Function:
Input:
Output:
Series:
Control Type
Cooling only
Heating only
2-Pipe system
4-Pipe system
Flying lead sensor with 2 m cable
Flying lead duct sensor 12cm immersion depth, 2m cable
Flying lead duct sensor 20cm immersion depth, 2m cable
Duct sensor with housing, 12cm immersion depth
Duct sensor with housing, 20cm immersion depth
Outdoor sensor
U = Vertical (2x4") housing, Standard is square housing
2 = 2 = 2-Pipe, 4 = 4-Pipe
T = Temperature, H = Humidity
M = Modulating, B = Binary
TCY
Key-data
Compact PI controller with:
2 TI, 1 AO
1 TI, 2 AO
© Vector Controls GmbH, Switzerland
www.vectorcontrols.com
TCY-MT
PI-temperature controller
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Vector TCY-MT2-W01

  • Page 1 Tn10 as Room sensor and SDB-Tn10-20 with AMI-S10 as immersion sensor. Modulating Actuators: Choose actuators with an input signal type of 0–10V DC or 2–10V DC. Doc: 70-00-0058 V1.2, 20160322 © Vector Controls GmbH, Switzerland Page 1 Subject to alteration www.vectorcontrols.com...
  • Page 2: Technical Specifications

    Power case: ø 58 x 32 mm (ø 2.3” x 1.3”) Weight (including package) 252 g (8.9 oz) Dimensions [mm] (inch) 88 (3.5) 32 (1.2) (0.8) Doc: 70-00-0058 V1.2, 20160322 © Vector Controls GmbH, Switzerland Page 2 Subject to alteration www.vectorcontrols.com...
  • Page 3: Installation

    Vector Controls or its affiliates cannot be held liable for any damage caused by such a failure.
  • Page 4: Display And Operation

    The connection to the temperature sensor may be interrupted or the temperature sensor is damaged. The output is switched off. Verify parameter settings and wiring. Doc: 70-00-0058 V1.2, 20160322 © Vector Controls GmbH, Switzerland Page 4 Subject to alteration www.vectorcontrols.com...
  • Page 5: Access To Parameters

    UP 02 Not used ON, OFF UP 03 Enable manual change of Heating/Cooling Mode. ON, OFF TCY-MT2-W01: OFF TCY-MT2-W02: OFF No influence on TCY-MT2-W01(cooling only)or TCY-MT2-W02 TCY-MT2: (heating only) TCY-MT4: UP 04 Not used ON, OFF UP 05 State after power failure:...
  • Page 6: Control Configuration

    Configuration of operation mode TCY-MT2: 0 - 2 TCY-MT2-W02: 1 TCY-MT4: 0 – 3 0 = TCY-MT2-W01 = Cooling mode Y TCY-MT2: 2 1 = TCY-MT2-W02 = Heating mode: Y TCY-MT4: 3 2 = TCY-MT2 = Heating and Cooling (2 pipe system), Y...
  • Page 7: Output Configuration

    Min cooling: CP15 Min heating: CP13 VAV actuator. The output limits may thus be set individually for heating and T [°C, F] U [V, mA] cooling mode: Doc: 70-00-0058 V1.2, 20160322 © Vector Controls GmbH, Switzerland Page 7 Subject to alteration www.vectorcontrols.com...
  • Page 8: Input Configuration

    Dry contact: Heating if contact closed CP23 > CP24 25°C (77F) 15°C (59F) Dry contact: Cooling if contact closed CP23 < CP24 15°C (59F) 25°C (77F) Doc: 70-00-0058 V1.2, 20160322 © Vector Controls GmbH, Switzerland Page 8 Subject to alteration www.vectorcontrols.com...

This manual is also suitable for:

Tcy-mt seriesTcy-mt2-w02Tcy-mt2Tcy-mt4

Table of Contents