Ferroli BLUEHELIX PRO RRT 24 C Instructions For Use & Installation page 166

Table of Contents

Advertisement

Available languages

Available languages

ON/OFF (A fig. 20) configuration
Table. 3- Switch A setting
DHW configuration
Parameter b06
b06=0
b06=1
b06=2
b01 = 1 o 3
b06=3
b06=4
b06=0
b06=1
b01 = 2 o 4
b06=2
b06=3
b06=4
166
BLUEHELIX PRO RRT 24 C
Contact open disables DHW and re-enables it if closed.
Contact open disables heating and displays F50. Contact closed enables heating.
The contact acts as a room thermostat.
Contact open displays F51 and the boiler continues to operate.
It is used as an alarm.
The contact acts as a limit thermostat, if open it displays F53 and turns off the request.
Contact open puts the boiler in ECO mode.
Contact closed puts the boiler in COMFORT mode.
Contact open disables heating and displays F50.
Contact closed enables heating.
The contact acts as a room thermostat
Contact open displays F51 and the boiler continues to operate.
It is used as an alarm.
The contact acts as a limit thermostat, if open it displays F53 and turns off the request.
cod. 3541Q530 - Rev. 00 - 10/2018
EN

Advertisement

Table of Contents
loading

Table of Contents