CALCULATION EXAMPLES OF OVERALL ACCURACY
[Example] Pt 100, 0 – 100°C, Output Type -5 – +5 V, Output
Range 1 – 5 V
2
3
Input Accuracy*
(0.15°C*
Output Range (10 V) ÷ Span (4 V) × 0.04 % = 0.25 %
*2, Calculate the accuracy in °C.
*3, 100°C × 0.1 % = 0.1°C ≤0.15°C. 0.15°C is used as input
accuracy value.
EXTERNAL VIEW
FRONT VIEW
Refer to the instruction manual for detailed procedures.
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)
23 (.91)
10 (.39)
SEN TRONIC
AG
Produkte, Support und Service
) ÷ Span (100°C) × 100 % + Max.
LED1 (LD1)
LED2 (LD2)
LED3 (LD3)
Configurator Jack
*Provided only for two-output type.
84 (3.31)
114 (4.49)
Rugghölzli 2
CH - 5453 Busslingen
SIDE VIEW
Output 1
Configuration DIP SW
1 2 3 4
ON
OFF
Output 2
Configuration DIP SW
1 2 3 4
ON
OFF
DIN RAIL
35mm wide
2
4.2x5
–
(.17x.20)
MTG HOLE
6 (.24) deep
11
M3
–
SCREW
[4 (.16)]
When mounting, no extra space is needed between units.
Tel. +41 (0)56 222 38 18
Fax +41 (0)56 222 10 12
MODEL: W2XR
*
SW2
SW1
6 (.23)
3
2
1
6
5
4
9
8 7
11
10
22 (.87)
29.5 (1.16)
mailbox@sentronic.com
www.sentronic.com
Need help?
Do you have a question about the W2XR and is the answer not in the manual?
Questions and answers