  • Page 2: Hardware Overview

    6 AI, 18 AO, 48 DIO, 1 MS/s AIO, 512 MB DRAM, Kintex-7 160T FPGA This document provides compliance, pinout, connectivity, mounting, and power information for the NI PXIe-7867R. Hardware Overview The following high-level block diagram represents the NI PXIe-7867R. Figure 1. NI PXIe-7867R Block Diagram 100 MHz Flash DDR3 RAM...
  • Page 3 Positive analog input signal connection Negative analog input signal connection AISENSE Reference connection for NRSE measurements AIGND Ground reference for the analog input signal Analog output signal connection AOGND Ground reference for the analog output signal 2 | ni.com | NI PXIe-7867R User Manual...
  • Page 4: Connectivity Options

    The provided clock source must be stable and glitch-free. Ground connection Supply (+5 V ) 5 V power output connection for external devices No connection The NI PXIe-7867R is protected from overvoltage and overcurrent conditions. Refer to the device specifications, available at ni.com/manuals for more Note information.
  • Page 5: Analog Input

    Analog Input The NI PXIe-7867R provides connections for six AI channels. Each channel has an AI+ pin, AI- pin, and AIGND pin to which you can connect both single-ended or differential voltage signals. Use the AISENSE pin to connect non-referenced single-ended signals.
  • Page 6: Connecting Differential Voltage Signals

    You can connect grounded or floating differential signal sources to the NI PXIe-7867R. Connect the positive voltage signal to the AI+ and the negative voltage signal to AI-. To connect grounded differential signals to the NI PXIe-7867R, you must also connect the signal reference to AI GND.
  • Page 7 Accessory Digital I/O The NI PXIe-7867R provides connections for 48 digital input/output (DIO) channels. Connector 0 contains 16 low-speed channels that can run up to 10 MHz signal frequencies and Connector 1 contains 32 high-speed DIO channels that can run up to 80 MHz signal frequencies.
  • Page 8: Field Wiring Considerations

    When the system powers on, the DIO channels are set as input low with pull-down resistors. To set another power-on state, you can configure the NI PXIe-7867R to load a VI when the system powers on. The VI can then set the DIO lines to any power-on state. Visit ni.com/info...
  • Page 9: Worldwide Support And Services

    Never connect the +5 V power terminals to analog or digital ground or Caution any other voltage source on the NI PXIe-7867R or any other device. Doing so can damage the device and the computer. National Instruments is not liable for damage resulting from such a connection.