  • Page 1 PARTS AND OPERATION MANUAL OPERATION AND PARTS MANUAL DCA-45USI ULTRA-SILENT SERIES GENERATOR PARTS LIST NO. M1871400004B Revision #2 (04/22/05) THIS MANUAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES.
  • Page 2 Discount-Equipment.com is your online resource for quality parts & equipment. Florida: 561-964-4949 Outside Florida TOLL FREE: 877-690-3101 Need parts? Click on this link: http://www.discount-equipment.com/category/5443-parts/ choose one of the options to help get the right parts and equipment you are looking for.
  • Page 3 PAGE 2 — DCA-45USI — OPERATION AND PARTS MANUAL (STD) — REV. #2 (04/22/05)
  • Page 4: Table Of Contents

    TABLE OF CONTENTS MQ POWER DCA-45USI MQ POWER DCA-45USI COMPONENT DRA COMPONENT DRA WINGS WINGS MQ POWER DCA-45USI MQ POWER DCA-45USI MQ POWER DCA-45USI COMPONENT DRA COMPONENT DRA COMPONENT DRAWINGS WINGS WINGS AC GENERA AC GENERA AC GENERA AC GENERATOR AC GENERA Generator Assembly ..........
  • Page 5: Dca-45Usi Specifications

    DCA-45USI — SPECIFICATIONS t a r i f i o i t i v l e i f , d l l e s a l i t r o t i t c r a t h t i l a r a t l a t l...
  • Page 6: Dimensions

    DCA-45USI — DIMENSIONS (SIDE AND FRONT) Figure 1. Dimensions DCA-45USI — OPERATION AND PARTS MANUAL (STD) — REV. #2 (04/22/05) — PAGE 7...
  • Page 7: Safety Message Alert Symbols

    NOTE instructions for the safe and efficient operation of the MQ Power Model DCA45USI ULTRA-SILENT™ GENERATOR. Explosive Fuel Before using this GENERATOR, ensure that the operating...
  • Page 8 DCA-45USI — SAFETY MESSAGE ALERT SYMBOLS Accidental Starting Respiratory Hazard ALWAYS place the engine ON/OFF switch in the OFF position, when the trowel is not ALWAYS wear approved respiratory protection. in use. Over Speed Conditions Sight and Hearing hazard NEVER tamper with the factory settings of the engine governor or settings.
  • Page 9: Rules For Safe Operation

    ■ NEVER use accessories or attachments, which are not is being transfer to a load. recommended by MQ Power for this equipment. Damage to ■ NEVER use a defective or frayed power cable. Check the the equipment and/or injury to user may result.
  • Page 10 DCA-45USI — RULES FOR SAFE OPERATION ■ ALWAYS make sure that electrical circuits are properly DANGER DANGER DANGER: DANGER DANGER grounded per the National Electrical Code (NEC) and local codes before operating generator. Severe injury or death! by electrocution can result from operating an ungrounded generator.
  • Page 11 DCA-45USI — RULES FOR SAFE OPERATION Battery ■ NEVER run engine without air filter. Severe engine damage may occur. The battery contains acids that can cause injury to the eyes ■ ALWAYS service air cleaner frequently to prevent engine and skin. To avoid eye irritation, always wear safety glasses. Use well insulated gloves when picking up the battery.
  • Page 12: Towing Safety Precautions

    DCA-45USI — RULES FOR SAFE OPERATION ■ Avoid sharp turns. Towing Safety Precautions ■ Trailer should be adjusted to a level position at all times CAUTION: CAUTION: CAUTION: CAUTION: CAUTION: when towing. ■ Raise and lock trailer wheel stand in up position when Conform to Department of Transportation transporting.
  • Page 13 DCA-45USI — INSTALLATION Figure 2. Typical Generator Grounding Application PAGE 14 — DCA-45USI — OPERATION AND PARTS MANUAL (STD) — REV. #2 (04/22/05)
  • Page 14 DCA-45USI — INSTALLATION Generator Grounding Outdoor Installation To guard against electrical shock and possible damage to Install the generator in a clear area. Make sure the generator the equipment, it is important to provide a good EARTH is on secure level ground so that it cannot slide or shift ground.
  • Page 15 DCA-45USI — TOWING SAFETY PRECAUTIONS ■ ALWAYS attach trailer’s safety chain to bumper of towing Towing Safety Precautions vehicle. CAUTION CAUTION CAUTION: CAUTION CAUTION ■ ALWAYS make sure the vehicle and trailer directional, Check with your local county or state safety backup, brake, and trailer lights are connected and working properly.
  • Page 16: Trailer Specifications

    DCA-45USI — TRAILER SPECIFICATIONS CAUTION CAUTION CAUTION: 5. Frame Width - Measurement is from fender to fender CAUTION CAUTION 6. Jack Stand - Trailer support device with maximum pound ALWAYS make sure the trailer is in good requirement from the tongue of the trailer. operating condition.
  • Page 17: Generator Decals

    DCA-45USI — GENERATOR DECALS The DCA-45USI generator is equipped with a number of safety decals. These decals are provided for operator safety and maintenance information. The illustration below and on the preceding page show the decals as they appear on the machine.
  • Page 18 DCA-45USI — GENERATOR DECALS DCA-45USI — OPERATION AND PARTS MANUAL (STD) — REV. #2 (04/22/05) — PAGE 19...
  • Page 19: General Information

    Generator " Open-Delta " excitation system. The open delta system consist of The MQ Power Model DCA-45USI (Figure 4) is a 36 kW an electrically independent winding wound among stationary generator that is designed as a high quality portable (requires windings of the AC output section.
  • Page 20 DCA-45USI — MAJOR COMPONENTS t a r r o j f f u r e l y l b y l b r i A y l b r o t y l b y l b y l b e t t y l b Figure 4.
  • Page 21 DCA-45USI — GENERATOR CONTROL PANEL Figure 5. Generator Control Panel Located behind the generator control panel is the Generator The definitions below describe the controls and functions of Control Box . This box contains some of the necessary the DCA-45USI " Generator Control Panel " (Figure 5). electronic components required to make the generator Main Circuit Breaker –...
  • Page 22 DCA-45USI — ENGINE OPERATING PANEL The definitions below describe the controls and functions of the DCA-45USI " Engine Operating Panel " (Figure 6). Panel Light - Normally used in dark places or at night. When activated, panel will luminate. When the generator is not in use, turn the panel light switch to the OFF position.
  • Page 23 DCA-45USI — OUTPUT TERMINAL PANEL FAMILIARIZATION Output Terminal Panel Output Terminal Familiarization The Output Terminal Panel (Figure 7) shown below is located The “ Output Terminal Panel ” (Figure 7) is provided with the on the right-hand side (left from control panel) of the generator. following: Lift up on the cover to gain access to receptacles and terminal Three (3) 120/240V output receptacles, 50 amp...
  • Page 24 DCA-45USI — OUTPUT TERMINAL PANEL FAMILIARIZATION 120 VAC GFCI Receptacles Each auxilliary receptacle is protected by a 50 amp circuit breaker. These breakers are located directly above the GFCI There are two 120 VAC, 20 amp GFCI (Duplex Nema 5-20R) receptacles.
  • Page 25 DCA-45USI — OUTPUT TERMINAL PANEL FAMILIARIZATION Connecting Loads Blower Fan Loads can be connected to the generator by using the Output This unit has an intake fan located at the rear of the machine Terminal Lugs or the convienience receptacles to draw outside air into the cabinet to cool the engine.
  • Page 26: Load Application

    DCA-45USI — LOAD APPLICATION Single Phase Load Three Phase Load When calculating the power requirements for 3-phase power Always be sure to check the nameplate on the generator and equipment to insure the wattage, amperage, frequency, use the following equation: and voltage requirements are satisfactorily supplied by the generator for operating the equipment.
  • Page 27 DCA-45USI — GENERATOR OUTPUTS Voltage Selector Switch Generator Amperage The voltage selector switch (Figure 15) is located above Table 7 describes the generator’s current output capability the UVWO Hard Wire Hook-up Panel. It has been provided for both 1Ø-phase and 3Ø phase applications. for ease of voltage selection.
  • Page 28: Gauge Reading

    DCA-45USI — GAUGE READING How to Read the Output Terminal Gauges. Reading Amperage The gauges and selector switches on the control panel To determine the amperage at a terminal lug, set the DO NOT effect the generator output. They are provided to AC Ammeter Change-Over Switch to the appropriate setting (Figure 19) to activate the AC Ammeter Gauge help observe how much power is being supplied at the Out-...
  • Page 29 DCA-45USI — OUTPUT TERMINAL PANEL CONNECTIONS 3Ø 208V/1Ø120V Output Terminal Lug Voltages UVWO Terminal Output Voltages 1. Place the voltage selector switch in the 3Ø 240/139 Various output voltages can be obtained using the using the Output Terminal Lugs . The voltages at the terminals are position as shown in Figure 24.
  • Page 30 DCA-45USI — OUTPUT TERMINAL PANEL CONNECTIONS 3Ø 480/277 Output Terminal Lug Voltages 1Ø 240V/120V Output Terminal Lug Voltages 1. Place the voltage selector switch in the 3Ø 480/277 1. Place the voltage selector switch in the 1Ø 240/120 position as shown in Figure 26. position as shown in Figure 28.
  • Page 31 DCA-45USI — PRE-SETUP Fuel Check Circuit Breakers DANGER: DANGER: DANGER: DANGER: DANGER: To protect the generator from an overload, a 3-pole, 110 amp, main circuit breaker is provided to protect the UVW output Fuel spillage on a hot! engine can cause a terminals from overload.
  • Page 32 DCA-45USI — PRE-SETUP Refueling Procedure: Open cabinet doors on the generator. Locate and remove the fuel tank cap and fill tank (Figure 33). DANGER: DANGER: DANGER: DANGER: DANGER: Diesel fuel and its vapors are dangerous to your health and the surrounding environment. Avoid skin contact and/or inhaling fumes.
  • Page 33 DCA-45USI — PRE-SETUP Coolant (Ethylane Glycol [Green] / Water — 50/50 mix) Use only drinkable tap water. If hard water or water with When the antifreeze is mixed with NOTE many impurities is used, the inside of the engine and radiator water, the antifreeze mixing ratio may become coated with deposits and cooling efficiency must be less than 50%.
  • Page 34 DCA-45USI — PRE-SETUP Battery When connecting battery do the following: This unit is of negative ground DO NOT connect in reverse. 1. NEVER connect the battery cables to the battery Always maintain battery fluid level between the specified terminals when the ignition switch is in the PRE-HEAT/ marks.
  • Page 35: Generator Start-Up Procedure

    DCA-45USI — GENERATOR START-UP PROCEDURE 3. Close all engine enclosure doors (Figure 40). WARNING: WARNING: WARNING: WARNING: WARNING: The engine's exhaust contains harmful emissions. ALWAYS have adequate ventilation when operating . Direct exhaust away from nearby personnel. Before Starting CAUTION: Figure 40.
  • Page 36 DCA-45USI — GENERATOR START-UP PROCEDURE 6. Turn the ignition key to the START position (Figure 44). 9. The generator's voltage meter (Figure 46) displays the Once the engine starts, release the ignition key and output voltage in VOLTS. allow it to return to the PRE-HEAT/RUN position (Figure 42).
  • Page 37 DCA-45USI — GENERATOR START-UP PROCEDURE 15. Turn the main , GFCI , and aux . circuit breakers to the 12. The engine oil pressure gauge (Figure 49) will indicate ON position (Figure 52). the oil pressure of the engine. Under normal operating conditions the oil pressure is approximately Figure 49.
  • Page 38: Generator Shut-Down Procedure

    DCA-45USI — GENERATOR SHUT-DOWN PROCEDURE Emergency Shut-down Procedure Normal Shut-down Procedure 1. To shut-down the engine in the event of an emergency, To shutdown the generator, use the following procedure: switch the MAIN , GFCI and LOAD (Figure 54) circuit 1.
  • Page 39 DCA-45USI — MAINTENANCE s l e r i A e t t d i c l e v t l e i t i d s l e r o f s t r e t l i o t t l i F r e t r e t...
  • Page 40 DCA-45USI — MAINTENANCE CAUTION: CAUTION: CAUTION: CAUTION: CAUTION: Air Removal If air enters the fuel injection system of a diesel engine, Allow engine to cool when flushing out starting becomes impossible. After running out of fuel, or radiator. Flushing the radiator while hot could after disassembling the fuel system, bleed the system cause serious burns according to the following procedure.
  • Page 41 Discount-Equipment.com is your online resource for quality parts & equipment. Florida: 561-964-4949 Outside Florida TOLL FREE: 877-690-3101 Need parts? Click on this link: http://www.discount-equipment.com/category/5443-parts/ choose one of the options to help get the right parts and equipment you are looking for.
  • Page 42: Trailer Brakes Maintenance

    DCA-45USI — TRAILER BRAKES MAINTENANCE Brakes Hydraulic Surge Brakes Trailer brakes should be inspected the first 200 miles of Hydraulic surge brakes (Figure 56) should not require any operation. This will allow the brake shoes and drums to seat special attention with the exception of routine maintenance properly.
  • Page 43 DCA-45USI — TRAILER MAINTENANCE Suspension Tires/Wheels/Lug Nuts The leaf suspension springs and associated components Tires and wheels are a very important and critical (Figure 57) should be visually inspected every 6,000 miles components of the trailer. When specifying or replacing the for signs of excessive wear, elongation of bolt holes, and trailer wheels it is important the wheels, tires, and axle are loosening of fasteners.
  • Page 44 DCA-45USI — TRAILER MAINTENANCE Lug Nut Torque Requirements It is extremely important to apply and maintain proper wheel mounting torque on the trailer. Be sure to use only the fasteners matched to the cone angle of the wheel. Proper procedure for attachment of the wheels is as follows: 1.
  • Page 45: Trailer Wiring Diagram

    DCA-45USI — TRAILER WIRING DIAGRAM Figure 59. Trailer/Towing Vehicle Wiring Diagram DCA-45USI — OPERATION AND PARTS MANUAL (STD) — REV. #2 (04/22/05) — PAGE 45...
  • Page 46: Engine Wiring Diagram

    DCA-45USI — ENGINE WIRING DIAGRAM Figure 60. Engine Wiring Diagram PAGE 46 — DCA-45USI — OPERATION AND PARTS MANUAL (STD) — REV. #2 (04/22/05)
  • Page 47 DCA-45USI — ENGINE WIRING DIAGRAM Figure 60. Engine Wiring Diagram(Continued) DCA-45USI — OPERATION AND PARTS MANUAL (STD) — REV. #2 (04/22/05) — PAGE 47...
  • Page 48: Generator Wiring Diagram

    DCA-45USI — GENERATOR WIRING DIAGRAM Figure 61. Generator Wiring Diagram PAGE 48 — DCA-45USI — OPERATION AND PARTS MANUAL (STD) — REV. #2 (04/22/05)
  • Page 49 DCA-45USI — TROUBLESHOOTING (GENERATOR) Practically all breakdowns can be prevented by proper handling and maintenance inspections, but in the event of a breakdown, use the table (Table 19) shown below for basic Generator Troubleshooting. If the problem cannot be remedied, consult our company's business office or service plant.
  • Page 50: Explanation Of Codes In Remarks Column

    EXPLANATION OF CODE IN REMARKS COLUMN How to read the marks and remarks used in this parts book. Items Found In the “Remarks” Column Serial Numbers-Where indicated, this indicates a serial number range (inclusive) where a particular part is used. Model Number-Where indicated, this shows that the corresponding part is utilized only with this specific model number or model number variant.
  • Page 51: Suggested Spare Parts

    DCA-45USI — SUGGESTED SPARE PARTS DCA-45USI w/ ISUZU BB-4JG1T 1 TO 3 UNITS Qty. Description 3 ..8970497081 ....OIL FILTER 3 ..8943692993 ....FUEL FILTER 3 ..0602046681 ....AIR ELEMENT 1 ..0602122272 ....UNIT, OIL PRESSURE 1 ..
  • Page 52 DCA-45USI — GENERATOR ASSY. GENERATOR ASSY. PAGE 52 — DCA-45USI — OPERATION AND PARTS MANUAL (STD) — REV. #2 (04/22/05)
  • Page 53 DCA-45USI — GENERATOR ASSY. GENERATOR ASSY. PART NO. PART NAME QTY. REMARKS B3110100202 ROTOR ASSY. FIELD ASSY. 8051070003 0010310035 HEX, HEAD BOLT 0042510000 SPRING WASHER 8041611004 COUPLING DISK 8041015003 BALANCING PLATE ..........1 ..... PURCHASE SET OF 1-16 0010310025 HEX, HEAD BOLT 0042510000 SPRING WASHER 8001026013...
  • Page 54 DCA-45USI — CONTROL BOX ASSY. CONTROL BOX ASSY. PAGE 54 — DCA-45USI — OPERATION AND PARTS MANUAL (STD) — REV. #2 (04/22/05)
  • Page 55 DCA-45USI — CONTROL BOX ASSY. CONTROL BOX ASSY. PART NO. PART NAME QTY. REMARKS M1214000102 CONTROL BOX 0601808825 CIRCUIT BREAKER, 3-POLE, 110A ....1 ..... KAF361101039 0021005080 MACHINE SCREW 0601823863 RELAY UNIT ............2 ..... MSA9013A 0027104016 MACHINE SCREW 0601820671 AUTOMATIC VOLTAGE REGULATOR ....1 ..... NTA-5A-2DB 0027105016 MACHINE SCREW 0601806116...
  • Page 56 DCA-45USI — CONTROL BOX ASSY. CONTROL BOX ASSY. PAGE 56 — DCA-45USI — OPERATION AND PARTS MANUAL (STD) — REV. #2 (04/22/05)
  • Page 57 DCA-45USI — CONTROL BOX ASSY. CONTROL BOX ASSY. PART NO. PART NAME QTY. REMARKS 0601840073 RHEOSTAT(VOLTAGE REGULATOR) ....1 ..RA20A2SE102BJ 2W 1K OHM 0601840121 KNOB 0602100009 STARTER SWITCH ..........1 ..ISUZU 897044-4180 8944024980 IGNITION KEY 0602103092 PREHEAT LAMP ..........1 ..PL-05 0601810245 BULB, E-10 T-10 DC18V 0602120095...
  • Page 58 DCA-45USI — ENGINE AND RADIATOR ASSY. ENGINE AND RADIATOR ASSY. PAGE 58 — DCA-45USI — OPERATION AND PARTS MANUAL (STD) — REV. #2 (04/22/05)
  • Page 59 DCA-45USI — ENGINE AND RADIATOR ASSY. ENGINE AND RADIATOR ASSY. PART NO. PART NAME QTY. REMARKS M1924200014 ENGINE ...............1 ..ISUZU BB-4JG1T 897049-7081 CARTRIDGE, OIL FILTER ........1 ..REPLACES 0602041214 0605000048 RUBBER SUSPENSION 0030010000 HEX, NUT 0040010000 SPRING WASHER 0041210000 PLAIN WASHER M1923200084 RADIATOR ............1 ..
  • Page 60 DCA-45USI — ENGINE AND RADIATOR ASSY. ENGINE & RADIATOR ASSY. PAGE 60 — DCA-45USI — OPERATION AND PARTS MANUAL (STD) — REV. #2 (04/22/05)
  • Page 61 DCA-45USI — ENGINE AND RADIATOR ASSY. ENGINE & RADIATOR ASSY. PART NO. PART NAME QTY. REMARKS 0603300285 ROCKNUT 0605511395 VALVE 0603306395 HOSE JOINT 0602021070 0269200310 DRAIN HOSE M2320300103 DRAIN JOINT M920020004 PLUG 0150000018 O-RING 0016906016 HEX, HEAD BOLT 0199100850 DRAIN HOSE 0605515106 HOSE BAND M9300000003...
  • Page 62 DCA-45USI — OUTPUT TERMINAL ASSY. OUTPUT TERMINAL ASSY. PAGE 62 — DCA-45USI — OPERATION AND PARTS MANUAL (STD) — REV. #2 (04/22/05)
  • Page 63 DCA-45USI — OUTPUT TERMINAL ASSY. OUTPUT TERMINAL ASSY. PART NO. PART NAME QTY. REMARKS M1230700103 TERMINAL PANEL M9220100204 OUTPUT TERMINAL BOLT M9220100104 TIE SCREW 0039310000 HEX, NUT 0040010000 SPRING WASHER 0041410000 PLAIN WASHER 0016908025 HEX, HEAD BOLT M1236100613 TERMINAL COVER M1236100704 OUTPUT WINDOW 0605010040...
  • Page 64 DCA-45USI — BATTERY ASSY. BATTERY ASSY. PAGE 64 — DCA-45USI — OPERATION AND PARTS MANUAL (STD) — REV. #2 (04/22/05)
  • Page 65 DCA-45USI — BATTERY ASSY. BATTERY ASSY. PART NO. PART NAME QTY. REMARKS 0602220187 BATTERY M9310500014 BATTERY SHEET M9103000304 BATTERY BAND 0602220920 BATTERY BOLT SET 0040006000 SPRING WASHER M1347200004 BATTERY CABLE M1347200104 BATTERY CABLE 0016910020 HEX, HEAD BOLT 0040510000 TOOTHED WASHER CABLE, GROUND ..........1 .....
  • Page 66 DCA-45USI — MUFFLER ASSY. MUFFLER ASSY. PAGE 66 — DCA-45USI — OPERATION AND PARTS MANUAL (STD) — REV. #2 (04/22/05)
  • Page 67 DCA-45USI — MUFFLER ASSY. MUFFLER ASSY. PART NO. PART NAME QTY. REMARKS M1331100102 MUFFLER 0017112030 HEX, HEAD BOLT M1334000003 EXHAUST PIPE 0602320101 GASKET .............1 ..894369-0210 0039308000 HEX, NUT 0602325088 SEAL CLAMP DCA-45USI — OPERATION AND PARTS MANUAL (STD) — REV. #2 (04/22/05) — PAGE 67...
  • Page 68 DCA-45USI — FUEL TANK ASSY. FUEL TANK ASSY. PAGE 68 — DCA-45USI — OPERATION AND PARTS MANUAL (STD) — REV. #2 (04/22/05)
  • Page 69 DCA-45USI — FUEL TANK ASSY. FUEL TANK ASSY. PART NO. PART NAME QTY. REMARKS M1364000102 FUEL TANK 0605505070 FUEL TANK CAP 0605501072 FUEL SENDER UNIT 0605516090 GASKET M1364200004 TANK BAND M9310500104 SUPPORTER SHEET 0016908020 HEX, HEAD BOLT 0016908065 HEX, HEAD BOLT 0207008000 HEX, NUT 0191301300...
  • Page 70 DCA-45USI — ENCLOSURE ASSY. ENCLOSURE ASSY. PAGE 70 — DCA-45USI — OPERATION AND PARTS MANUAL (STD) — REV. #2 (04/22/05)
  • Page 71 DCA-45USI — ENCLOSURE ASSY. ENCLOSURE ASSY. PART NO. PART NAME QTY. REMARKS M1414000202 BASE M1494000004 ACOUSTIC SHEET M1414800003 ENVIRONMENTAL TANK 0603306797 PLUG,1-1/2 0017110040 HEX, HEAD BOLT M1424000012 FRONT FRAME M1494100004 ACOUSTIC SHEET ..........1 ..S/N 8200001 TO 8200080 M1493104804 ACOUSTIC SHEET ..........1 ..S/N 8200081~ M1311600004 RADIATOR COVER 0016908020...
  • Page 72 DCA-45USI — ENCLOSURE ASSY. ENCLOSURE ASSY. PAGE 72 — DCA-45USI — OPERATION AND PARTS MANUAL (STD) — REV. #2 (04/22/05)
  • Page 73 DCA-45USI — ENCLOSURE ASSY. ENCLOSURE ASSY. PART NO. PART NAME QTY. REMARKS 0040016000 SPRING WASHER 0041216000 PLAIN WASHER 0010116040 HEX, HEAD BOLT 0040016000 SPRING WASHER 0041216000 PLAIN WASHER M1444000102 REAR FRAME M1494300003 ACOUSTIC SHEET M1444800004 DUCT M1494300204 ACOUSTIC SHEET 0207006000 HEX, NUT 0016908020 HEX, HEAD BOLT...
  • Page 74 DCA-45USI — ENCLOSURE ASSY. ENCLOSURE ASSY. PAGE 74 — DCA-45USI — OPERATION AND PARTS MANUAL (STD) — REV. #2 (04/22/05)
  • Page 75 DCA-45USI — ENCLOSURE ASSY. ENCLOSURE ASSY. PART NO. PART NAME QTY. REMARKS M1494400404 ACOUSTIC SHEET M1454000103 SIDE DOOR M1494400104 ACOUSTIC SHEET M1454000503 SIDE DOOR M1494400504 ACOUSTIC SHEET M1454000303 SIDE DOOR M1494400304 ACOUSTIC SHEET M9113000002 DOOR HANDLE ASSY. C9312500004 SEAL RUBBER 0021806016 MACHINE SCREW 0030006000...
  • Page 76 DCA-45USI — RUBBER SEALS ASSY. RUBBER SEALS ASSY. PAGE 76 — DCA-45USI — OPERATION AND PARTS MANUAL (STD) — REV. #2 (04/22/05)
  • Page 77 DCA-45USI — RUBBER SEALS ASSY. RUBBER SEALS ASSY. PART NO. PART NAME QTY. REMARKS 0229200950 SEAL RUBBER 0228901385 SEAL RUBBER 0228900900 SEAL RUBBER 0229400900 SEAL RUBBER 0228900795 SEAL RUBBER 0028900590 SEAL RUBBER 0229400445 SEAL RUBBER 0228800455 SEAL RUBBER 0228900445 SEAL RUBBER 0229200455 SEAL RUBBER 0228100870...
  • Page 78 DCA-45USI — NAMEPLATE AND DECALS ASSY. NAME PLATE ASSY. PAGE 78 — DCA-45USI — OPERATION AND PARTS MANUAL (STD) — REV. #2 (04/22/05)
  • Page 79 DECAL, CONNECTION OF OUTPUT CABLE ....1 ..... M92020000 M9520200104 DECAL, OVER CURRENT RELAY ....... 1 ..... C92020010 M1561000004 DECAL, MQ POWER ........... 3 ..... S/N 8200001 TO ...................... 8200080 M1561000004 DECAL, MQ POWER ........... 2 ..... S/N 8200081~ M1561100004...
  • Page 80 Discount-Equipment.com is your online resource for quality parts & equipment. Florida: 561-964-4949 Outside Florida TOLL FREE: 877-690-3101 Need parts? Click on this link: http://www.discount-equipment.com/category/5443-parts/ choose one of the options to help get the right parts and equipment you are looking for.