Hotpoint HD5G00KCW/UK Manual page 8

Hide thumbs Also See for HD5G00KCW/UK:
Table of Contents

Advertisement

Control Knobs for the gas burners
The position of the gas burner controlled by each one of the knobs is shown by a solid ring
the burners, hold a lighted match or lighter near the burner and, at the same time, press down and turn the
corresponding knob counter clockwise to the maximum
minimum or intermediate power. Shown on the knob are the different symbols for off
when the symbol corresponds with the reference mark on the control panel), for maximum
obtain these settings, turn the knob counter clockwise with respect to the off position. To turn off the burner, turn the
knob clockwise until it stops (corresponding again with the
Electronic Ignition for the Gas Hob*
This device operates when a slight pressure is applied to the button marked with
burner just press the button
corresponding knob all the way in and turning it
counter-clockwise until it lights. For immediate lighting,
first press the button and then turn the knob.
Should the burner flames accidentally go out,
turn off the control knob and wait at least 1 minute
before trying to relight.
Since the hob burners are equipped with a safety
device, you must hold the control knob in for about 3-7
seconds after the burner has been lighted to allow the
gas to pass until the safety thermocouple has heated.
Technical data
Technical data
Technical data
Technical data
Technical data
Voltage and Frequency 220-240V~ 50-60Hz
Table 1
Burner
Fast
(Large)(R)
Semi Fast
(Medium)(S)
Auxiliary
(Small)(A)
Oven
Grill
Supply
Pressures
*
At 15°C and 1013 mbar- dry gas
**
Propane
8
while pushing the
Diameter
Thermal Power
kW (p.c.s.*)
(mm)
Nominal
Reduced
100
94
3,00
0,7
75
69
1,90
0,4
51
46
1,00
0,4
-
2,50
0,6
-
2,50
1,3
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
P.C.S. = 50,37 MJ/Kg
setting. Each burner can be operated at its maximum,
symbol).
HOB GAS BURNER
SAFETY DEVICE
Liquid Gas
By-Pass
Nozzle
1/100
1/100
(mm)
(mm)
***
41
87
218
30
70
138
30
52
73
36
71
182
63
80
182
28-30
20
35
***
Butane P.C.S. = 49,47 MJ/Kg
Natural P.C.S. = 37,78 MJ/m
. To light one of
(the knob is on this setting
and minimum
. To
symbol. To light a specific
ELECTRONIC
LIGHTING DEVICE
S
S
A
R
Natural Gas
****
Flow*
Nozzle
g/h
1/100
**
(mm)
214
128
136
104
71
76
179
115
179
122
37
20
25
17
45
25
3
Flow*
l/h
286
181
95
238
238

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hd5g00kcb/uk

Table of Contents