Maintenance; Troubleshooting - Ryobi AirStrike P360VN Operator's Manual

Table of Contents

Advertisement

Available languages

Available languages

WARNING:
When servicing, use only identical replacement parts.
Use of any other parts could create a hazard or cause
product damage.
PROBLEM
Work-contacting element does not
depress fully - tool does not operate.
Tool operates properly, but fasteners do
not drive fully
Tool operates properly, but fasteners are
driven too deep
Tool jams frequently
Tool stops and LEDs flash rapidly
Tool has charged battery and LEDs
are slowly flashing or LEDs do not turn
off after approximately ten seconds of
non-use.
AFTER FRENCH AND SPANISH LANGUAGE SECTIONS.

MAINTENANCE

TROUBLESHOOTING

POSSIBLE CAUSE
Low staples
Work-contacting element is jammed
Air pressure is too low
Depth of drive isn't deep enough
Staple is too long for wood hardness
Air pressure is too high
Depth of drive is too deep
Incorrect staples
Damaged staples
Loose magazine
Dirty magazine
Battery is low or has no charge
Tool is hot
Tool has malfunctioned
NOTE: ILLUSTRATIONS START ON PAGE 12
GENERAL MAINTENANCE
Avoid using solvents when cleaning plastic parts. Most
plastics are susceptible to damage from various types of
commercial solvents and may be damaged by their use. Use
clean cloths to remove dirt, dust, oil, grease, etc.
11 — English
SOLUTION
Replenish staples
Remove battery and clear debris
Increase air pressure
Adjust depth of drive
Use staple length that is appropriate
for wood
Decrease air pressure
Adjust depth of drive
Verify that staples are the correct size
Replace staples
Tighten screws
Clean magazine
Recharge battery
Allow tool to cool
Take tool to nearest authorized repair
center

Advertisement

Table of Contents
loading

This manual is also suitable for:

Airstrike p360

Table of Contents