5 GALLON WET/DRY VAC Operation Manual MODEL #’s VOC507S 3801 This safety alert symbol identifies important safety messages in this manual. Failure to follow this important safety information may result in serious injury or death.
WARRANTY We take pride in producing a high quality, durable product. This Black ™ Diamond product carries a limited two (2) year warranty against defects in workmanship and materials from date of purchase under normal household use. If product is to be used for commercial, industrial, or rental use, a 90 day limited warranty will apply.
IMPORTANT SAFETY INSTRUCTIONS READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE USING THIS VACUUM. Read and understand this operator’s manual and all labels on the Wet/Dry Vacuum cleaner before operating. Safety is a combination of common sense, staying alert and knowing how your vacuum works. Use this Wet/Dry Vacuum only as described in this manual.
Page 5
• To reduce the risk of injury from accidental starting, unplug power cord before changing or cleaning filter. • Do not leave Wet/Dry Vac unattended when plugged in. Unplug from outlet when not in use and before servicing. • Turn off Wet/Dry Vac before unplugging. •...
DOUBLE INSULATION INSTRUCTIONS This Wet/Dry Vac is double-insulated, eliminating the need for a separate grounding system. Use only identical replacement parts. Read the instructions for Servicing Double-Insulated Wet/Dry Vacs before servicing. Use this Wet/Dry Vac as described in this manual. Observe the following warnings that appear on the motor housing of your Wet/Dry Vac.
EXTENSION CORDS When using an extension cord with your Wet/Dry Vacuum refer to the following table to determine the required A.W.G. wire size. Before using the cleaner make sure the power cord and extension cord are in good working condition. Make repairs or replacements before using the vacuum cleaner.
UNPACKING & CHECKING CARTON CONTENTS Remove all contents from the box. Remove the power head and take out any contents inside the collection tank. Check each item against the carton contents list. Carton Contents List: Description Qty. Vac Assembly ...........1 Hose ..............1 Extension Wand ..........
GENERAL ASSEMBLY INSTRUCTIONS A Philips head screw driver is required. WARNING DO NOT PLUG POWER CORD INTO POWER OUTLET. MAKE SURE PLUG IS DISCONNECTED BEFORE ASSEMBLING THE WET/DRY VAC. UNPACKING YOUR WET/DRY VACUUM & GENERAL ASSEMBLY 1. Verify that the power cord is disconnected from the outlet (Fig. 1). 2.
POLARIZED PLUG To reduce the risk of electrical shock, this appliance has a polarized plug (one blade wider than the other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug.
Page 11
4. Place the power head back on the collection tank and secure it in place using the latches (Fig. 5). OPERATING INSTRUCTIONS: DRY VACUUMING 5. Insert the locking end of the hose into the vacuum port on the power head and lock in place. Push the required attachment onto the free end of the hose or extension (Fig.
LIQUID VACUUM OPERATION LIQUID VACUUM CLEANING WARNING BE SURE TO READ, UNDERSTAND, AND APPLY, INFORMATION ENTITLED ‘IMPORTANT SAFETY INSTRUCTIONS’. DO NOT VACUUM IN AREAS WITH FLAMMABLE GASES, VAPORS, OR EXPLOSIVE DUSTS IN THE AIR. FLAMMABLE GASES OR VAPORS INCLUDE BUT ARE NOT LIMITED TO: LIGHTER FLUID, SOLVENT TYPE CLEANERS, OIL-BASED PAINTS, GASOLINE, ALCOHOL, OR AEROSOL SPRAYS.
Page 13
IMPORTANT! When vacuuming large quantities of liquids, do not immerse the nozzle completely in the liquid; leave a gap at the tip of the nozzle opening to allow air inflow. The machine is fitted with a float valve that stops the suction action when the collection tank reaches its maximum capacity.
BLOWER OPERATION This Wet/Dry Vac has blowing capabilities. To use the blower feature follow the instructions listed. WARNING ALWAYS WEAR SAFETY GOGGLES COMPLYING WITH ANSI Z87.1 (OR IN CANADA, CSAZ94.3) BEFORE USING BLOWER. CAUTION: KEEP BYSTANDERS CLEAR FROM BLOWING DEBRIS. WEAR A DUST MASK IF BLOWING CREATES DUST THAT MIGHT BE INHALED.
MAINTENANCE 1. Verify that the power cord is disconnected from the outlet (Fig. 1). 2. Disconnect the hose from the vacuum (Fig. 2). 3. Undo the latches and remove the power head from the collection tank (Fig. 3). 4. Clear all dirt or debris from the collection tank and hose (Fig. 4). 5.
INSTALLING & CLEANING REUSABLE CLOTH FILTER INSTALLING REUSABLE CLOTH FILTER 1. Verify that the power cord is disconnected from the outlet. 2. Remove power head and place in upside down position. 3. Slide reusable cloth filter down over the filter cage making sure the cage is completely covered (Fig.
INSTALLING & CLEANING FOAM WET FILTER INSTALLING FOAM WET FILTER 1. Verify that the power cord is disconnected from the outlet. 2. Remove power head and place in upside down position. Follow instructions to remove cloth filter in the section above. 3.
TROUBLESHOOTING WARNING TO REDUCE THE RISK OF ELECTRIC SHOCK, UNPLUG BEFORE TROUBLESHOOTING. PROBLEM POSSIBLE CAUSE SOLUTION Check the power supply, cord, No power supply. breakers, and fuses. Unplug and check the power cord. Faulty power cord. If damaged, have it repaired by a The wet/dry vacuum will not professional.
PARTS LIST Part Part Number Description Quantity 551058101 Handle Assembly Power Head Assembly 551416106 Float 551005104 Filter Cage 551086101 Latch Assembly Stainless Steel Collection Tank 551016105 Vacuum Port Assembly 551038112 Base 551012121 Casters 551038113 Static Discharge Chain 551003108 Hose 551003109 Extension Wands 551296103 Floor Nozzle...