Steam; Operating Pressure Values - Miele PDR 514 Operating And Installation Instructions

Commercial tumble dryers
Table of Contents

Advertisement

Installation
 Gas lines and screw connections may leak after connection and conversion work.
Gas may escape.
After connection and conversion work, the gas lines, all screw connections (including
those on the jets), and the locking bolts on the measuring stubs must be checked to en-
sure they are leak-tight. This check must be performed both while the appliance is at a
standstill and while it is in operation.
Settings with natural gas
Tumble
dryers
Partial heating
PDR 914/514
9.2 kW
PDR 918/518
11.1 kW
PDR 922/522
14.4 kW
PDR 928/528
18.4 kW
PDR 944/544
22.2 kW
Settings with liquid propane
Tumble dryers
Partial heating
PDR 914/514
8.3 kW
PDR 918/518
10 kW
PDR 922/522
13 kW
PDR 928/528
16.6 kW
PDR 944/544
20 kW

Steam

The steam connection may only be carried out by a certified installer.
In addition to these installation instructions, the information from the data plate, wiring
diagram, and documentation accompanying the appliance must also be noted and com-
plied with when connecting steam-heated Miele appliances.

Operating pressure values

High-pressure steam version, indirect
Tumble dryer
Tumble dryer TR
For efficiency, the operating pressures must not fall below the specified values.
48
Heater rating
Full heating
16.7 kW
20.0 kW
23.9 kW
33.3 kW
40.0 kW
Heater rating
Full heating
15 kW
18 kW
21.5 kW
30 kW
36 kW
HP indir.
Jet diameter
Partial heating
1/8"
36 mpsi
(3.5 mm)
(2.5 mbar)
3/16"
33 mpsi
(4 mm)
(2.3 mbar)
3/16"
39 mpsi
(4.4 mm)
(2.7 mbar)
2 x 1/8"
36 mpsi
(2 x 3.5 mm)
(2.5 mbar)
2 x 3/16"
33 mpsi
(2 x 4 mm)
(2.3 mbar)
Jet diameter
Partial heating
1/16"
145 mpsi
(2.05 mm)
(10 mbar)
1/16"
122 mpsi
(2.2 mm)
(8.4 mbar)
1/8"
145 mpsi
(2.4 mm)
(10 mbar)
2 x 1/16"
145 mpsi
(2 x 2.05 mm)
(10 mbar)
2 x 1/16"
122 mpsi
(2 x 2.2 mm)
(8.4 mbar)
Minimum operating pres-
sure
87 psi / 600 kPa / 6 bar
58 psi / 400 kPa / 4 bar
Jet pressure
Full heating
123 mpsi
(8.5 mbar)
102 mpsi
(7.0 mbar)
106 mpsi
(7.3 mbar)
123 mpsi
(8.5 mbar)
109 mpsi
(7.5 mbar)
Jet pressure
Full heating
0.39 psi
(27 mbar)
0.39 psi
(27 mbar)
0.39 psi
(27 mbar)
0.39 psi
(27 mbar)
0.39 psi
(27 mbar)
Maximum operating pres-
sure
145 psi / 1,000 kPa / 10 bar
72 psi / 500 kPa / 5 bar