SystemAir SAVE VTR 300/B User Manual

SystemAir SAVE VTR 300/B User Manual

Hide thumbs Also See for SAVE VTR 300/B:

Advertisement

Quick Links

SAVE VTR 300/B
User Manual
© 2016 Copyright Systemair AB
Systemair AB can accept no responsibility for possible errors in catalogues, brochures and other printed
material. Systemair AB reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without sub sequential changes being
necessary in specifications already agreed.
All rights reserved.
208349-EN_GB
Document in original language
2016-04-13 A004

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SAVE VTR 300/B and is the answer not in the manual?

Questions and answers

Summary of Contents for SystemAir SAVE VTR 300/B

  • Page 1 Systemair AB can accept no responsibility for possible errors in catalogues, brochures and other printed material. Systemair AB reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without sub sequential changes being necessary in specifications already agreed.
  • Page 2: Table Of Contents

    Contents 1 Disposal and recycling ....................... 1 2 Warnings........................... 1 3 Product description ........................1 3.1 Left and Right models ....................... 2 4 Configuration ..........................2 4.1 Control panel ........................2 4.1.1 Display symbols...................... 3 4.2 Setting the temperature ....................3 4.3 Manual setting of airflow ....................
  • Page 3: Disposal And Recycling

    • Duct connections/duct ends must be covered during storage and installation. 3 Product description The SAVE VTR 300/B is a heat recovery ventilation unit with a built in rotating heat exchanger. The SAVE VTR 300/B is suitable for houses with up to 240 m heated living area.
  • Page 4: Left And Right Models

    ENTER menu choices or settings by pressing the button RETURN button Step RETURN in the menu levels and to abort an initiated parameter change and restore the original value by pressing the button SAVE VTR 300/B User Manual Systemair Sverige AB 208349...
  • Page 5: Display Symbols

    The supply air temperature is set manually in steps of 1 K in the main menu display by choosing the temperature symbol. If an electrical re-heater is installed the temperature setpoints are: 12-22 °C. For installed water re-heater the setpoints are: 12-40 °C. SAVE VTR 300/B User Manual Systemair Sverige AB 208349...
  • Page 6: Manual Setting Of Airflow

    ENTER button after each Locked YES/NO set digit and choose "NO" for the system not be locked. 3. Go to: Week program Service Week program 4. Choose Week program again. Week program Airflow SAVE VTR 300/B User Manual Systemair Sverige AB 208349...
  • Page 7: Manual And Automatic Summer Mode

    The unit will automatically alternate between winter operation with heat recovery and summer operation without heat recovery. 5 Maintenance of the unit Maintenance of the SAVE VTR 300/B should normally be performed 3 - 4 times a year. SAVE VTR 300/B User Manual...
  • Page 8: Warnings

    If type G3 filters are used instead of F7 , the system curve for Supply Fan (SF) must be changed: For G3 type filter: 11–20, for F7 type filter: 1–10. See Installation and Service Instruction. SAVE VTR 300/B User Manual...
  • Page 9: Resetting The Filter Time

    Press the RETURN button until you reach the main menu. 5.5 Checking and cleaning the heat exchanger Danger Make sure that the Mains supply to the unit is disconnected before performing any maintenance or electrical work! SAVE VTR 300/B User Manual Systemair Sverige AB 208349...
  • Page 10 Ensure the rotor motor is not exposed to moisture 6. Remount the heat exchanger. Don’t forget to reconnect the heat exchanger power and sensor cables. 7. Close and lock the front hatch and connect the unit to mains. SAVE VTR 300/B User Manual Systemair Sverige AB...
  • Page 11: Cleaning The Fans

    Allow the fans to dry properly before remounting. 6. Remount the fans. Don’t forget to reconnect the fan power cables. 7. Close the front hatch and connect the unit to mains. SAVE VTR 300/B User Manual Systemair Sverige AB 208349...
  • Page 12: Replacing Rotor Drive Belt

    6. Press the drive-belt ends firmly towards each other to secure the nipple. 7. Pull the drive belt on to the belt pulley and rotate the exchanger by hand. Check that the belt pulley rotates. SAVE VTR 300/B User Manual Systemair Sverige AB...
  • Page 13: Heat Exchanger Removed

    5.8 Overheat protection reset button If the supply air temperature is low, it can indicate that the over heat protection is triggered. The overheat protection can be reset by pressing the reset button (1). SAVE VTR 300/B User Manual Systemair Sverige AB...
  • Page 14: Duct System Maintenance

    Leaves and pollution could plug up the air intake grille and reduce the capacity. Check the air intake grille, and clean as necessary. It is recommended to do this at least twice a year. Fig. 7 Intake grill SAVE VTR 300/B User Manual Systemair Sverige AB...
  • Page 15: Checking The Roof Cowl (If Fitted)

    A triggered frost protection alarm results in the EMT/Fr- (in case of installed water heating following: battery) or triggered overheat • Both fans stop. • Outdoor and exhaust air dampers closed. SAVE VTR 300/B User Manual Systemair Sverige AB 208349...
  • Page 16: Type Label

    Before calling your service representative, make a note of the specification and production number from the type label, which can be found on the side of the units, next to the external connections. SAVE VTR 300/B User Manual Systemair Sverige AB...
  • Page 17 Fig. 9 Type label Position Description Product code (product specification) Product item number Production order number Serial number Production date (YY.MM.DD) SAVE VTR 300/B User Manual Systemair Sverige AB 208349...
  • Page 18 Systemair Sverige AB reserves the right to make changes and improvements to the contents of this manual without prior notice. Systemair UAB Linų st. 101 LT–20174 Ukmergė, LITHUANIA Phone +370 340 60165 Fax +370 340 60166 www.systemair.com...