Page 1
Vorna Valley, 1686 Yokohama Business Park, 20 Indianapolis Street, 134 Godocho, Hodogaya, Instruction Manual Kyalami Business Park, Yokohama, Kanagawa 240-0005 Kyalami, Midrand Japan RS-927A South Africa www.rs-components.com www.rs-components.com Stock No: 264-7228 U.S.A Asia Allied Electronics RS Components Ltd. 7151 Jack Newell Blvd. S.
Page 2
True RMS Autoranging Digital Multimeter / English 1.Introduction • The meter measures AC/DC Voltage, AC/DC Current , Resistance, Diode Test, Continuity Capacitance, Frequency and Temperature. • The meter also offers a Non-Contact AC Voltage detector. • Proper use and care of this meter will provide many years of reliable service. 2.
True RMS Autoranging Digital Multimeter / English True RMS Autoranging Digital Multimeter / English 3. Description 2-3. International Safety Symbols 3-1. Meter Description This symbol adjacent to another symbol, terminal or operating device indicates that the operator must refer to an explanation in the Operating instructions to avoid 1.
True RMS Autoranging Digital Multimeter / English True RMS Autoranging Digital Multimeter / English 3-2.Symbols Used on LCD Display 4-2. RANGE Button 1. Auto Power 0ff • When the meter is first turned on, it automatically goes into Auto Ranging. 2.
Page 5
True RMS Autoranging Digital Multimeter / English True RMS Autoranging Digital Multimeter / English 5.Operating Instructions 5-2.Frequency (Electronic) Measurement 5-1.AC/DC Voltage (Frequency) Measurement WARNING: Observe all safety precautions when working on live voltages. 1. Set the rotatory function switch to the Hz Position. WARNING: Observe all safety precautions when working on live voltages.
True RMS Autoranging Digital Multimeter / English True RMS Autoranging Digital Multimeter / English 5-3.AC/DC Current Measurement 5-4. Resistance Measurement WARNING: Observe all safety precautions when working on live circuits. Measurements in WARNING: Never test resistance on a live circuit the 10A range should be limited to 30 seconds maximum every 15 minutes.
Page 7
True RMS Autoranging Digital Multimeter / English True RMS Autoranging Digital Multimeter / English 5-5.Diode Test 5-6.Continuity Check WARNING: Never test diodes in a live circuit. WARNING: Never test continuity on a live circuit. 1. Set the rotary function switch to the Ω CAP Position.
True RMS Autoranging Digital Multimeter / English True RMS Autoranging Digital Multimeter / English 5-7.Capacitance Measurement 5-8.Temperature Measurement WARNING: To avoid electric shock, disconnect power to the unit under test and discharge WARNING: Do not touch the temperature probe to live circuits. all capacitors before taking any capacitance measurements.
True RMS Autoranging Digital Multimeter / English True RMS Autoranging Digital Multimeter / English 5-9. Non-Contact AC Voltage Detection 6.Maintenance and Cleaning WARNING: Risk of Electrocution. Before use, always test the Voltage Detector on a known This Multimeter is designed to provide years of dependable service, if the following care live circuit to verify proper operation.
True RMS Autoranging Digital Multimeter / English True RMS Autoranging Digital Multimeter / English 9. Specifications Function Range Resolution Accuracy 400.0Ω 0.1Ω Function Range Accuracy 4.000kΩ 0.001kΩ 400.0mV 0.1mV ±(1.2% + 5 digits) 40.00kΩ 0.01kΩ 4.000mV 0.001V Resistance 400.0kΩ 0.1kΩ DC Voltage 40.00V 0.01V...
True RMS Autoranging Digital Multimeter / English 9-2. General Specifications Insulation Class 2, Double Insulation Diode Test Test current 1mA max., open circuit voltage of 3V typical Continuity Test Audible signal if the resistance is <50Ω Low Battery Indication “ ” is displayed Display 4000 count LCD Over Range Indication...
Need help?
Do you have a question about the RS-927A and is the answer not in the manual?