Kenwood TH-D75A User Manual page 42

Hide thumbs Also See for TH-D75A:
Table of Contents

Advertisement

Available languages

Available languages

D-STAR
Chart for checking whether signals reach the repeater
Phenomenon
No message is returned
from the access repeater
after transmission. (S-meter
indicator also does not
move.)
The access repeater
Callsign and <
>
appear after transmission.
The destination repeater
Callsign and <
>
appear after transmission.
40
Cause
In case that the selection for the repeater you are
using (access repeater) is incorrect.
In case that the repeater frequency is incorrect
(or the duplex setting is incorrect).
In case that it is out of the repeater area (or the
signal does not reach the repeater).
In case that your Callsign is not registered to the
D-STAR management server or the registered
information is different.
In case that the other station's Callsign is not
registered to the D-STAR management server or
the registered information is different.
In case that a destination repeater can not be
reached or the destination repeater is in use.
Treatment
Set the correct access repeater to [FROM].
Set the repeater frequency (or the duplex setting) correctly.
Move to a location where the signal reaches the repeater or
access another repeater that the signal will reach.
Register your Callsign to the D-STAR management server or
check the registered information.
Check the registration status of the other station's Callsign on
the D-STAR management server (only when the other station
is open in public.)
Wait a while and call again.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Th-d75e

Table of Contents