1.2.10.1. alterations in system surroundings

No alterations may be made to the following devices:
Heater unit
Gas, air inlet, water or electricity (pipe)lines
Flue gas exhaust pipe
Safety valve or heating water runoff pipe, and to any structural components that could affect the reliability of the Unit.
Note: XRGI system components must not be modified without EC POWER's prior consent in writing.

1.2.10.2. explosive and highly inflammable substances

Do not use or store any explosive or highly inflammable substances, such as petrol, paper or inks, in the area where the unit is
installed. Do not use any sprays, solvents, chlorine-based cleaners, dyes, adhesives, etc. close to the Unit. Such substances
not only provide ignition risks, but may also cause corrosion, e.g. in the flue gas unit.

1.2.11. Transportation and accommodation

The Power Unit weighs around 750 kg. The risks pass to the client when the XRGI system is handed over to the shipper or
carrier or when it leaves the works or dispatch warehouse, whichever is the sooner, even if Carriage Paid To destination is
agreed (T&Cs section 5).
The best way of shipping the Power Unit is on a platform truck for Euro pallets. In order to lift the Power Unit the platform truck
must be brought underneath the device fully and centrally. The Power Unit must be installed in one piece, and must not be put
vertically or laid on its side when being shipped. Tip angles of 45-50, e.g. when the Unit is carried over steps, by crane, etc.
must not be exceeded. It cannot be delivered in parts and assembled on site. See section 2.1.1.2 for Power Unit dimensions.
Damages to the Power Unit cannot be ruled out completely, despite all quality assurance measures. Should the Power Unit
be badly damaged, e.g. the engine or generator, it can only be repaired at the factory. So bear in mind that the Power Unit
may have to be removed again as a whole. For the terms and conditions governing the installation and removal costs in these
cases, please see the sales and partnership contracts.

1.2.12. Base

The Power Unit must be put on a level base to avoid movements due to vibration. The base must be strong enough to carry
the Unit's weight. The base must be watertight and non-inflammable.