1.
Select heater location. Allow clearances as indicated below between heater and all other materials.
(See Fig. 1)
2.
Make sure that the outside area to where the flue pipe will reach is clear of any objects.
(See Fig. 2 & 3)
CAUTION! The standard flue pipe installation, as shown in Fig. 2, is for wall thickness from 4 in. to 9 in.
ONLY.
NOTE: For wall thickness more than 9 in., refer to page 18 for available flue pipe extensions.
NOTE: The flue pipe can be installed through any standard building materials.
Combustible object
Not less than 2 ft.
Fig. 2

INSTALLATION OF HEATER AND FLUE PIPE

Combustible object
Noncombustible object
Not less than 2 ft.
45˚
Not less than 1 ft.
Flue pipe
* Not less than 8 in.
Standard Flue Pipe Installation
Fig. 1
Not less than
* Be sure this
clearance will
be maintained
after snowfalls,
etc.
Not less than 1.5 ft.
1.5 ft.
Fig. 3