Turning Heater Off; Section F; Routine Maintenance - Toyotomi Toyostove Laser 56 Installation And Operation Instruction Manual

Laser clean heating system/vented heater
Table of Contents

Advertisement

Press ON/OFF switch to "OFF" position. (AUTO lamp and temperature lamp will
go out. Burning mode lamp will flash until flame disappears.) Circulation fan and
blower motors continue to run for approx. three (3) minutes to cool down the
heater. Make sure ON/OFF lamp goes out when the fan stops.
Note:
If ON/OFF switch is pressed to "ON" position during the cool down peri-
od, the heater will automatically re-start at the end of cool down period.
Note:
Disconnect the heater plug from the electrical outlet after the power lamp
has turned off if the heater will go unused for a prolonged period. The
plug should also be disconnected during electrical storms.
Note:
Heater may also be shut down by lowering the setting on the temp. selec-
tor thermostat(s) because heater goes into "OFF" cycle.
Important:
This feature is for testing purpose only!
This heater also can be kept burning at desired combustion mode (High, Medium or Low) manually, regardless of room
temperature.
1.
Press the "HOUR" button and "MINUTE" button at the same time for more than three (3) seconds when
ON/OFF switch is "ON".
2.
P1, P2 or P3 will be displayed on the Digital Indicator;
Then select desired combustion mode by pressing "MINUTE" or "HOUR" button. "MINUTE" button changes com-
bustion mode to higher, "HOUR" button changes combustion mode to lower.
3.
To clear, press the "HOUR" button and "MINUTE" button at the same time for more than three (3) seconds until
normal temperature display returns.

SECTION F:

ROUTINE MAINTENANCE

12

TURNING HEATER OFF

MANUAL COMBUSTION
P1 = Low mode
P2 = Medium mode
P3 = High mode
HOUR