en Basic operation
7.2 Switching off the appliance
Switch the appliance off when you are not using it.
Press
​ ⁠ to switch the appliance off.
a The appliance switches off. Any functions currently
in progress are cancelled.
7.3 Selecting a fan setting
Press
​ ⁠   or
​ ⁠ .
a The LED for the set fan setting lights up in the LED
display.
7.4 Switching on intensive mode
If particularly strong odours or vapours develop, you
can use intensive mode.
​ ⁠   so oft drücken, bis in der LED-Anzeige die LED 4
1.
für die Intensivstufe 1 leuchtet.
​ ⁠   so oft drücken, bis in der LED-Anzeige die LED 5
2.
für die Intensivstufe 2 leuchtet.
a After approx. 6 minutes, the appliance automatically
switches to fan setting 3.
7.5 Switching off intensive mode
To select a fan setting of your choice, press
7.6 Switching on the fan run-on
Press
​ ⁠ .
a LED 1 for the fan setting lights up in the LED dis-
play. LED 6 flashes for the fan run-on.
a The appliance switches off automatically after ap-
prox. 10 minutes.
7.7 Switching off the fan run-on
Press
​ ⁠ .
a This immediately stops the fan run-on.
a The appliance switches to the fan setting that was
previously selected.
7.8 Switching on automatic mode
The optimum fan setting is set automatically using a
sensor.
Press
​ ⁠ .
a In the LED display, LED 6 lights up for automatic
mode.
7.9 Switch off automatic mode
Press
​ ⁠ .
a The appliance switches to the fan setting that was
previously set.
a The ventilation is automatically ended when the
sensor detects no further change in the room air
quality.
a Automatic mode runs for a maximum of four hours.
1
Depending on the appliance specifications
8
​ ⁠ .
1
1
7.10 Intermittent ventilation
With interval ventilation, the ventilation system switches
on and off in the selected setting for the selected time.
Note: This function is only available in the Home Con-
nect app.
If the interval ventilation is switched on, LED 6 continu-
ously flashes in the LED display for the interval ventila-
tion and the LED for the selected fan setting lights up.
As soon as the ventilation time ends, the LED for the
fan setting you have selected goes out. LED 6 contin-
ues to flash.
7.11 Sensor control
In automatic mode, a sensor in the appliance detects
the intensity of the cooking and roasting fumes. De-
pending on the setting of the sensor sensitivity, the op-
timum fan setting is automatically switched on.
If the sensor control system reacts too weakly or too
strongly, the setting for the sensor sensitivity may
change.
¡ Default setting: Fan setting 3
¡ Lowest setting: Fan setting 1
¡ Highest setting: Fan setting 5
7.12 Setting the sensor control
Requirement: The appliance is switched off.
Press and hold
​ ⁠   and
1.
Press
​ ⁠   or  ​ ⁠ to change the setting.
2.
To cancel the setting, press  ​ ⁠ .
To save the setting, press and hold
3.
prox. 3 seconds.
Or wait approx. 10 seconds until the setting is
saved automatically.
a A signal tone sounds as soon as the selected set-
ting is saved.
7.13 Setting the saturation indicator
The saturation indicator must be adjusted depending
on the filter used.
Requirement: The appliance is switched off.
Press and hold
​ ⁠   and
1.
To set circulating-air mode (non-regenerable fil-
ter), press
​ ⁠ / ​ ⁠ until LED 2 lights up in the LED
display.
To set circulating-air mode (non-regenerable fil-
ter), press
​ ⁠ / ​ ⁠ until LED 3 lights up in the LED
display.
To convert the electronic control back to opera-
tion without the air recirculation filter, press
until LED 1 lights up on the LED display.
To save the setting, press and hold  ​ ⁠   and  ​ ⁠   for ap-
2.
prox. three seconds.
Or wait approx. 10 seconds until the setting is
saved automatically.
To cancel the setting, press  ​ ⁠ .
a A signal tone sounds as soon as the selected set-
ting is saved.
1
1
​ ⁠   for approx. 3 seconds.
​ ⁠   and  ​ ⁠ for ap-
​ ⁠   for approx. three seconds.
​ ⁠ / ​ ⁠