Summary of Contents for PCB Piezotronics ICP M102B06
Page 1
High frequency ICP® pressure sensor, 500 psi, 10 mV/psi, M10x1 mtg thd, accel. comp., ground isolated Installation and Operating Manual For assistance with the operation of this product, contact the PCB Piezotronics, Inc. Toll-free: 716-684-0001 24-hour SensorLine: 716-684-0001 Fax: 716-684-0987 E-mail: info@pcb.com...
Assistance is needed to safely operate equipment PCB Piezotronics is an ISO-9001 certified company whose Damage is visible or suspected calibration services are accredited by A2LA to ISO/IEC Equipment fails or malfunctions 17025, with full traceability to SI through N.I.S.T.
Page 3
CAUTION Refers to hazards that could damage the instrument. NOTE Indicates tips, recommendations and important information. The notes simplify processes and contain additional information on particular operating steps. The following symbols may be found on the equipment described in this manual: This symbol on the unit indicates that high voltage may be present.
Page 5
Component Name Hazardous Substances Lead (Pb) Mercury (Hg) Cadmium (Cd) Chromium VI Polybrominated Polybrominated Compounds Biphenyls (PBB) Diphenyl Ethers (Cr(VI)) (PBDE) Housing PCB Board Electrical Connectors Piezoelectric Crystals Epoxy Teflon Electronics Thick Film Substrate Wires Cables Plastic Solder Copper Alloy/Brass This table is prepared in accordance with the provisions of SJ/T 11364.
Page 6
OPERATION MANUAL FOR QUARTZ PRESSURE SENSORS SERIES 102 SERIES 113 INTRODUCTION The figure above shows the components of the basic probe, i.e. the piezoelectric element and the ® This series of miniature dynamic pressure sensors is source follower amplifier. These components ®...
OPERATION MANUAL FOR QUARTZ PRESSURE SENSORS SERIES 102 SERIES 113 M10x 1.0 threaded adaptor with floating seal to allow A silicone rubber coating approximately .010” thick adjustment of diaphragm mounting depth where it is has also been proven effective in many applications. necessary to adapt to various wall thicknesses.
Page 8
Generally, static methods are not employed below several hundred ICP is a registered trademark of PCB Piezotronics seconds time constant. To employ static means, direct couple the sensor to the DVM readout using a T-Connector from the sensor jack or use the Model 484B06 or 482C24 in the calibrate mode.
Page 9
All specifications are at room temperature unless otherwise specified. 3425 Walden Avenue, Depew, NY 14043 In the interest of constant product improvement, we reserve the right to change specifications without notice. ® is a registered trademark of PCB Piezotronics, Inc.
Page 10
PCB Piezotronics Inc. claims proprietary rights in REVISIONS the information disclosed hereon. Neither it nor any reproduction thereof will be disclosed to others DESCRIPTION without the written consent of PCB Piezotronics Inc. UPDATED OVERALL LENGTH TOLERANCE, UPDATED NOTE 5 53183 ELECTRICAL CONNECTOR 10-32 UNF - 2A...