Gardner Denver AirSmart ELECTRA-SAVER Operating And Service Manual page 74

Stationary base-mounted compressor
Table of Contents

Advertisement

Maintenance Action
Change Air Filter ...................................................................
Change Oil Separator ..........................................................
Check Reservoir Oil Level ...................................................
Check for Proper Load/Unload.............................................
Check Discharge Pressure/Temp ........................................
Check Dirt Accumulation on Cooler .....................................
Change Oil Filter Element ....................................................
Change Compressor Lubricant (AEON 9000 SP) * ............
Check Relief Valve ...............................................................
* See Oil Change Interval Chart,
MAINTENANCE SCHEDULE
As Indicated by
AirSmart
Controller
·
·
·
·
, page 58, for specific lubricant life.
Figure 5-7
13-21-608
Page 73
Every
Every
Every 8
125
1000
Hours
Hours
Hours
·
·
·
·
·
Every
Every
8000 *
Year
Hours
·
·
·

Advertisement

Table of Contents
loading

This manual is also suitable for:

Airsmart electra-saver iiEaq99wEbq99rEau99abEbu99h