7" Vacuum
Right Angle Sander
Safety, Operation and Maintenance – Save This Document and Educate All Personnel
Model
Disc Size
52597
7"
SANDER
Find The Most Current Offering of Support Documents and Accessories at www.Dynabrade.com
Read and understand this tool manual before operating your air tool. Follow all safety rules for the protection of operating personnel as
well as adjacent areas. Always operate, inspect and maintain this tool in accordance with the American National Standards Institute
(ANSI). Safety Requirements for the Use, Care and Protection of Abrasive Wheels – ANSI B7.1, Compressed Air and Gas Institute (CAGI)
Safety Code for Portable Air Tools – CAGI B186.1, Code of Federal Regulation – CFR 29 Part 1910, International Organization for
Standardization (ISO) Hand Held Non-Electric Power Tools – ISO 11148, Safety Requirements and applicable State and Local Regulations.
Read and understand tool manual before work starts
to reduce risk of injury to operator, visitors, and tool.
Ear protection to be worn when exposure to sound,
exceeds the limits of applicable Federal, State or
local statues, ordinances and/or regulations.
Respiratory protection to be used when exposed to
contaminants that exceed the applicable threshold
limit values required by law.
Some dust created by sanding, grinding, drilling, and other construction activities contain chemicals known to cause cancer, birth defects
or other reproductive harm. Some examples of these chemicals are:
• Lead from lead-based paints
• Crystalline silica from bricks and cement and other masonry products
• Arsenic and chromium from chemically treated lumber
Your risk from these exposures varies, depending on how often you do this type of work. To reduce your exposure to these chemicals: work in a well
ventilated area, and work with approved safety equipment, such as those dust masks that are specially designed to filter out microscopic particles.
Carefully Read and Understand the General
and Die Grinder sections found in Tool Safety
and Operating Guidelines (PN00001676)
Before Handling or Using Tool.
Tool Intent: 7
" Vacuum RightAngle Sander is ideal for non-sparking material removal using abrasive discs with appropriate back-up pads.
An appropriate external vacuum source is required that is suitable for material being processed.
DO NOT USE Tool for Anything Other Than Its Intended Applications.
Training: Proper care, maintenance, and storage of your air tool will maximize tools performance and reduce chance for accident.
Employer's Responsibility: Provide operators with safety instructions and training for safe use of tools and accessories.
Report to Your Supervisor any Condition of the Tool, Accessories or Operation you Consider Unsafe.
Spindle
RPM
Thread
Connection
6,000
5/8"-11
1-1/4" (Threaded)

SAFETY and OPERATING INSTRUCTIONS

Vac.
WARNING
Eye protection must be worn at all times, eye
protection to conform to ANSI Z87.1.
Practice safety requirements. Work alert, have proper
attire, and do not operate tools under the influence
of alcohol or drugs.
Air line hazard, pressurized supply lines and flexible
hoses can cause serious injury. Do not use damaged,
frayed or deteriorated air hoses and fittings.
Carefully Read all instructions before operating or servicing
any Dynabrade
®
Abrasive Power Tool. Products offered by
Dynabrade are not to be modified, converted or otherwise
altered from the original design.
PD09.27R2
Effective July, 2022
Supercedes PD09.27R

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 52597 and is the answer not in the manual?

Questions and answers

Summary of Contents for Dynabrade 52597

  • Page 1 5/8"-11 1-1/4" (Threaded) SANDER Find The Most Current Offering of Support Documents and Accessories at www.Dynabrade.com WARNING Read and understand this tool manual before operating your air tool. Follow all safety rules for the protection of operating personnel as well as adjacent areas. Always operate, inspect and maintain this tool in accordance with the American National Standards Institute (ANSI).
  • Page 2 • Check all connections and air hoses for good condition Valve and proper installation. ‰ Ball • Dynabrade Air Power Tools are designed to operate at Valve Drain Air Hose 90 PSIG (6.2 Bar/620 kPa) maximum air pressure at the...
  • Page 3 • Refer to Dynabrade's Warning/Safety Operating Instructions Tag (Reorder No. 95903) for safety information. After maintenance is performed on tool, add a few drops of Dynabrade Air Lube (P/N 95842) to the air line and start the tool a few times to lubricate air motor.
  • Page 4 (Incld 97156 Ring) 17 N•m 98285 Spring Label Key 14 Housing (Includes: 01041 Gear Oil Part # Description Fitting,25275 Bushing) 02210 Model 52597 25285 S/N, RPM Label See Label Key 25283 Silencer 25287 Sanding Label 25217 Muffler Assembly 98282 O-Ring (2mm) 98281 O-Ring (2.4mm)
  • Page 5 Note: Rotating the valve stem while inserting prevents damage to the o-ring 2. Apply several drops of the Dynabrade Air Lube 10W/NR (P/N 95842 or equivalent) to valve seat pocket wall on the inside of the 25245 Throttle Handle before inserting the 51945 Valve Seat.
  • Page 6 3. Install 31909 Cuff onto shroud with 31943 Hose and 31905 Swivel Cuff through 50584 Hose Holder and adjust to proper angle. Then tighten 97206 Nut while holding 50581 Bushing. 4. Supply 3 drops of 95482 Dynabrade Air Lube 10W/NR (or equivalent) into the air inlet bushing of the tool while the throttle lever is depressed. Allowing the oil to flow into the air motor.
  • Page 7 This service chart is published as a guide to expectant life of component parts. The replacement levels are based on average tool usage over one year. Dynabrade Inc. considers one year usage to be 1,000 hours. Parts Common to all Models:...
  • Page 8 Part No. 96100 Part No. 95461 3/8" NPT. Dynabrade Air Lube • Formulated for pneumatic equipment. Dynabrade Angle Gear Oil • Absorbs up to 10% of its weight in water. • Specifically formulated to saturate wick system in right Part No. 95821: 4oz. (118 ml) angle gear head.