Malfunction
No audio
transmission to
remote station.
The unit does not
report an alarm.
The unit is not
operational after a
firmware upload.
Bosch Security Systems
All manuals and user guides at all-guides.com
Possible causes
Hardware fault.
Faulty cable connections. Check all cables, plugs,
Incorrect configuration.
The audio voice
connection is already in
use by another receiver.
Alarm source is not
selected.
No alarm response
specified.
Power failure during
programming by firmware
file.
Incorrect firmware file.
Installation Manual
Troubleshooting | en
Solution
Check that all connected
audio units are operating
correctly.
contacts and
connections.
Check audio parameters
on the Audio
configuration and
LIVEPAGE Functions
pages.
Wait until the connection
is free and then call the
sender again.
Select possible alarm
sources on the Alarm
sources configuration
page.
Specify the desired alarm
response on the Alarm
connections
configuration page; if
necessary change the IP
address.
Have the unit checked by
Customer Service and
replace if necessary.
Enter the IP address of
the unit followed by /
main.htm in your Web
browser and repeat the
upload.