Auto - Panasonic WH-SDC0309K3E5 Operating Instructions Manual

Air-to-water heatpump
Hide thumbs Also See for WH-SDC0309K3E5:
Table of Contents

Advertisement

Menus
For installer
Menu
6.3
*
*

Auto

1,
2
Automatic switch from Heat to
Cool or Cool to Heat.
*
The system is locked to operate without COOL mode. It can be unlocked only by authorised installers or our authorised service partners.
1
*
Only displayed when COOL mode is unlocked (This means when COOL mode is available).
2
44
Default Setting
Setting Options / Display
Water temp. for cooling ON
Cooling ON
temperatures in
Compensation curve
compensation curve
or direct input.
Water temp. for cooling ON Compensation curve
Input the 4
temperature points
X axis: 20 °C, 30 °C
(2 on horizontal X
Y axis: 15 °C, 10 °C
axis, 2 on vertical Y
axis)
• If 2 zone system is selected, the 4 temperature points must also be input for Zone
2.
• "Zone 1" and "Zone 2" will not appear on the display if only 1 zone system.
Water temp. for cooling ON Direct
Set temperature for
10 °C
Cooling ON
• If 2 zone system is selected, temperature set point must input for Zone 2.
• "Zone 1" and "Zone 2" will not appear on the display if only 1 zone system.
T for cooling ON
Set T for cooling ON
* This setting will not
5 °C
available to set when
pump fl owrate set to
Max. duty.
Outdoor temperatures for switching from Heat
to Cool or Cool to Heat.
Outdoor temp. for (Heat to Cool) /
Outdoor temp. for (Cool to Heat)
Outdoor temp. for (Heat to Cool)
Set outdoor
temperature for
15 °C
switching
from Heat to Cool.

Hide quick links:

Advertisement

Table of Contents
loading