Cool - Panasonic WH-SDC0309K3E5 Operating Instructions Manual

Air-to-water heatpump
Hide thumbs Also See for WH-SDC0309K3E5:
Table of Contents

Advertisement

Menu
6.2
*
*

Cool

1,
2
To set various water & ambient
temperatures for cooling.
*
The system is locked to operate without COOL mode. It can be unlocked only by authorised installers or our authorised service partners.
1
*
Only displayed when COOL mode is unlocked (This means when COOL mode is available).
2
Default Setting
Setting Options / Display
Outdoor temp. for heating OFF
Temperature for
24 °C
heating OFF
T for heating ON
Set T for heating
ON.
* This setting will not
5 °C
available to set when
pump fl owrate set to
Max. duty.
Heater ON/OFF
Heater ON/OFF Outdoor temp. for heater ON
Temperature for
0 °C
heater ON
Heater ON/OFF Delay time for heater ON
Delay time for heater
0:30 min
to turn on
Heater ON/OFF Water temperature for heater ON
Setting of water
temperature to turn
-4 °C
on from water set
temperature.
Heater ON/OFF Water temperature for heater OFF
Setting of water
temperature to turn
-2 °C
off from water set
temperature.
Water temperatures for cooling ON
and T for cooling ON.
43

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents