omake Omk.SBD01.E15.0101.Z5F User Manual page 32

Juice dispenser
Table of Contents

Advertisement

Available languages

Available languages

C0
0
C1
0
C2
0
C4
0
PARAM.
MINIMUM
d0
0
d3
0
PARAM.
MINIMUM
A1
-99
A4
-99
A5
-99
A7
0
PARAM.
MINIMUM
i0
0
i1
0
i2
-1
PARAM.
MINIMUM
NS
0
Second
99
x10
99
Minute
99
Minute
100
%
MAXIMUM
UNIT
99
Hour
99
Dakika
MAXIMUM
UNIT
°C / °F(1)
99
°C / °F
99
°C / °F
99
Minute
99
x10
MAXIMUM
UNIT
1
----
1
----
99
Minute
MAXIMUM
UNIT
99
X10000
The minimum time required for the
0
ignition to activate after the device
is energized.
Minimum time required for
5
compressor to start 2 consecutive
starts
The minimum time that the contact
3
must remain closed between the 2
contact activation times
Percentage of the compressor
50
running time during cabin sensor
fault (P1 alarm)
FACTORY
DEFROST
SETTINGS
How many hours to defrost
8
0 = defrost is never activated
30
How long will the defrost take?
FACTORY
ALARMS
SETTINGS
Low-temperature alarm value or
difference value depending on the
set value (If A5 is negative; A1 is
-99
the solid value, if positive, the set
value is the dependent differential
value)
For the high-temperature alarm,
the difference must be lower than
the set value (If A5 is negative; A4
99
is the solid value, if positive, the
set point is the connected
differential value.)
Reset differential for parameters
-2
A1 and A4
Delay for activation of temperature
alarm
2
Note: Temperature alarms are
disabled for 1 hour after the end of
the defrost.
FACTORY
DIGITAL INPUT
SETTINGS
Stopping the compressor by
0
triggering the door switch input
0 = No 1 = Yes
Type of door switch input
0
0 = normally closed
1 = normally open
Delay time "id" alarm code for the
door open alarm
30
-1 = the door open alarm never
goes off
FACTORY
OTHER
SETTINGS
0
The compressor starts limit for
30