Manually starting the defrost cycle;
The thermostat defrosts every 8 hours as per the factory settings. This time starts to run as
soon as electricity is supplied to the thermostat.
To start this cycle manually:
-
With DEFROST Press and
will start immediately and the led will
minutes.
Note: A manual defrost cycle always resets the defrost counter, a new defrost starts 8
hours later (or after the assigned d0 time). If the defrost values have been changed
while the first adjustments of the thermostat are being made, defrosting manually once
after the operations will allow resetting the current defrost cycle and defrosting
according to the newly assigned values.
TURNING THE THERMOSTAT ON AND OFF
-
You can switch the thermostat to standby mode by pressing the button for
4 seconds.
THERE IS NO WRITING ON THE SCREEN, ONLY IF THE DOT DISPLAY LED IS
LIGHTING, AND THE THERMOSTAT IS OFF.
POSSIBLE SYMBOLS AND WARNINGS THAT MAY BE VIEWED ON THE DISPLAY
LEADS
EXPLANATION
Compressor Led;
When lit steady, the ignition is on.
While it is flashing, it means that the set value is being changed or
the contact is getting ready to be activated.
Defrost Led;
When it is lit, defrost is active.
Low-Temperature Alarm;
AL
Check the room temperature and the value of parameter A1.
High-Temperature Alarm;
AH
Check the room temperature and the value of parameter A4.
Cabin Sensor Error;
P1
Check if the sensor is broken and make sure that the sensor is
connected properly.
Door Switch Alarm:
Id
Check the i0 and i1 parameters.
hold the button for 3 seconds. The defrost cycle
light up. By default, this defrost will take 30