This procedure allows any instrument menu access to be locked.
Select the menu that you wish to lock:
MENU → press ESC and ◄ at the same time for 3 seconds, the display shows
(the point on the left over the writing indicates that this item is now locked). If the operator attempts
to enter this menu, access is denied and is displayed.
MENU → press ENTER and ▲ at the same time for 3 seconds, the display shows
(the point on the left over the writing goes off to indicate that this item is now unlocked).
MENU → press ▲ and ◄ at the same time for 3 seconds: you can now enter and modify
all menus including the locked ones. By returning to weight display, the lock is restored.
WARNING: operations must only be performed after contacting technical assistance.
After each operation the display shows , press ENTER to continue.
By pressing ESC the procedure is cancelled and no changes are made.
Upon instrument power-on hold down the ESC key until the display shows , then proceed as
follows:
CONSTANTS RESTORE (does not erase the calibration): confirm , use arrow keys to select
, set code 6935 and confirm.
RESERVED FOR THE INSTALLER
MENU LOCKING
MENU UNLOCKING
TEMPORARY MENU UNLOCKING
DATA DELETION AND PROGRAM SELECTION
- 17 -