Setpoint Programming; Alarms - LAUMAS W100RIP Manual

Weight repeater
Table of Contents

Advertisement

From the weight display, press MENU to access the setpoint setting.
MENU →  →  →  :
- : connecting the E/EC option you can program 12 groups (classes) of different setpoint
values; otherwise you can only set the first class. The E/EC position selects the valid relay
release values.
-  (from 0 to max full scale; default: 0): setpoint, weight value above which contact switching
occurs. The type of switching can be set (see section OUTPUTS AND INPUTS
CONFIGURATION).
MENU →  :
-  (from 0 to max full scale; default: 0): hysteresis, value to be subtracted from the setpoint
to obtain contact switching threshold for the decreasing weight. For example, with SET = 100
and hysteresis = 10, switching occurs at 90 for the decreasing weight.
- : no serial port set as .
- : communication problems between transmitter and receiver; check instrument electrical
connections and settings.
- : maximum displayable value exceeded (value higher than 999999 or lower than -999999).
- : the weight display exceeds 110% of the full scale of transmitting instrument.
- : in transmitting instrument the  protocol has been set; change it to  protocol.
- : in transmitting instrument the  protocol has been set; change it to  protocol.

SETPOINT PROGRAMMING

ALARMS

- 15 -

Advertisement

Table of Contents
loading