Velleman DVM040 User Manual page 9

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
AC Voltage:
DC Current:
AC Current:
Resistance:
Range Select
Continuity Check
Diode Test
Data Hold
Battery Test (1.5V/3V/9V)
Over Range Indication
LED/flash Light
Backlight
Auto Power Off
Unit Icon Display
Low Battery Indication
Overrange Protection
NCV Detection
Live Wire Detection
True RMS Measurement
Battery
Product Size (mm)
Product Weight (g)
Safety Category
IP rating
Fuses
9.1 DC & AC VOLTAGE
Range
200mV
2V
20V
200V
1000(750)V
V. 01 – 04/05/2023
200mV / 2V / 20V / 200V / 750V
200μA / 2mA / 20mA / 200mA /2A / 10A
200μA / 2mA / 20mA / 200mA /2A / 10A
200Ω / 2kΩ / 20kΩ / 200kΩ / 2MΩ / 20MΩ
/200M Ω
Manual Range
Yes
Yes
Yes
No
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
9V (6F22) x 1
200x92x60
230
CATIII 1000V / CAT IV 600V
IP20
Replaceable
F 0.50 A / 1000 V, 6.35 x 32 mm ceramic
F 10A / 1000V, 6.35 x 32 mm ceramic
Maximum input voltage: 1000V DC or 750V AC RMS
Frequency range: 40Hz - 400Hz,
Resolution
100µV
1mV
10mV
100mV
1V
DVM040
Input impedance:10MΩ
Display: TRUE RMS
DCV Accuracy
±0.5%±3
±0.8%±3
±0.8%±3
±0.8%±3
±1%±5
9
ACV Accuracy
±1.0%±5
±1.0%±5
±1.0%±5
±1.0%±5
±1.2%±5
©Velleman Group nv