Wolf Steel TLV50 Quick Start Manual

Fuel conversion kits

Advertisement

Available languages

Available languages

Quick Links

INSTALLER: THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOME OWNER.
CHECK THE BOXES TO INDICATE THAT THE CORRESPONDING STEPS HAVE BEEN COMPLETED.
TLV50
Kit W175-0842, NG-P Includes:
1x Regulator
1x #52 Burner orifi ce
1x Propane pilot injector
1x Conversion data label
WARNING
!
If converting to propane, appliance must be power vented. Refer to installation manual for details.
This conversion kit shall be installed by a qualifi ed service agency in accordance with the manufacturer's instructions
and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is
not followed exactly, a fi re, explosion or production of carbon monoxide may result causing property damage, personal
injury or loss of life. The qualifi ed service agency is responsible for the proper installation of this kit. The installation is
not proper and complete until the operation of the converted appliance is checked as specifi ed in the owner instructions
supplied with the kit.
WARNING:
Failure to position the parts in accordance with these diagrams or failure to use only parts specifi cally approved with this appliance
may result in property damage or personal injury.
CAUTION:
Before proceeding with conversion the gas supply must be shut off prior to disconnecting the electrical power.
IMPORTANT:
We strongly recommend converting your appliance prior to fi nal installation and removing porcelain panels for conversion.
1. Remove the glass guard assembly or safety barrier, door trim and glass door. Remove existing
media and set aside.
2. Disengage the air shutter adjustment rod by pushing the smaller end of the rod to the left or right
(depending on model) (Fig. 1). The rubber grommet must stay in place.
3. Remove the screws that secure the entire burner assembly in place (the number varies by model)
(Fig. 2). Lift the entire burner assembly up and out of the appliance. Set aside.
4. Using a deep socket wrench, remove the orifi ce from within the fi rebox and replace with the
orifi ce supplied.
5. Remove the two screws from the valve regulator and remove the regulator, replace with the one
supplied (Fig. 2).
6. Remove the two (2) screws securing the pilot in place. Using a backup wrench, remove the pilot tube from the bottom side of
the pilot (Fig 3). Remove the pilot orifi ce and replace with the one supplied. Re-attach the pilot tube and pilot to the backet.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada •
FUEL CONVERSION KITS FOR MODELS:
TLV50 || TLV62 || TLV74
These kits are for use at altitudes of 0 to 4,500 feet.
TLV62
Kit W175-0843, NG-P Includes:
1x Regulator
1x #50 Burner orifi ce
1x Propane pilot injector
1x Conversion data label
Fig. 2
TLV74
Kit W175-0844, NG-P Includes:
1x Regulator
1x #49 Burner orifi ce
1x Propane pilot injector
1x Conversion data label
PILOT
ORIFICE
1(866)820-8686
www.napoleon.com
OR/OU
Fig. 1
Fig. 3
W415-4123 / A / 02.01.23

Advertisement

loading

Summary of Contents for Wolf Steel TLV50

  • Page 1 (Fig 3). Remove the pilot orifi ce and replace with the one supplied. Re-attach the pilot tube and pilot to the backet. Fig. 3 PILOT ORIFICE Fig. 2 W415-4123 / A / 02.01.23 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleon.com...
  • Page 2: Venturi Adjustment

    Appliance Propane TLV50 1/2” (13mm) TLV50 31,500 BTU/hr TLV62 1/2” (13mm) 38,000 BTU/hr TLV62 TLV74 1/2” (13mm) TLV74 41,500 BTU/hr W415-4123 / A / 02.01.23 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleon.com...
  • Page 3: Pressure Adjustment

    It’s important to periodically perform a visual check of the pilot and burner fl ames. Compare them to the illustrations provided. Peak Valley W415-4123 / A / 02.01.23 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleon.com...
  • Page 4 (Fig 3). Retirez l’injecteur et le remplacez avec l’un fourni. Réattachez le tube de pilote et le pilote au support. Fig. 3 PILOT INJECTEUR DE ORIFICE VEILLEUSE Fig. 2 W415-4123 / A / 02.01.23 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleon.com...
  • Page 5: Réglage Du Venturi

    fl amme. Il est recommandé de régler le volet par tranche de 1/8 po (0,32 cm). W415-4123 / A / 02.01.23 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleon.com...
  • Page 6: Ajustement De La Pression

    Il est important d’effectuer périodiquement une inspection visuelle de la fl amme de la veilleuse et du brûleur. Comparez-la à ces illustrations. Vallée W415-4123 / A / 02.01.23 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleon.com...

This manual is also suitable for:

Tlv62Tlv74